期刊文献+

基于平稳高斯过程的Lam bert修正定律

Modified Lambert theorem for stationary guass process
下载PDF
导出
摘要 论证了基于Lambert方程的动态测量中系统误差的存在性,并针对高斯分布物料模型的射线计数误差进行了分析,提出了基于平稳高斯过程的Lambert定律,同时对普遍存在于在线组分测量中的一种系统误差推导出其误差修正因子。 In this paper a kind of significant systematic effects in online measurement by radiation transmission is recognized. Then model the quantity in question by a stationary Gauss distribution so as to investigate the characteristics of radiation attenuation process, a systematic effect occurred in most online pattern detection is found and a quantificational correction is given to compensate this effect. A modified relationship between intensity and thickness, mass attention for Lambert theorem is given.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2003年第3期233-235,共3页 Nuclear Electronics & Detection Technology
关键词 Lambert方程 动态测量 系统误差 平稳高斯过程 Lambert修正定律 射线计数误差 高斯分布模型 元素分析 radiation transmission on-line coal ash content detection modified Lambert theorem systematic effect
  • 相关文献

参考文献3

  • 1张志康,林谦,衣宏昌.在线式γ射线煤灰分测量仪[J].洁净煤技术,1998,4(1):48-50. 被引量:2
  • 2Cywicka-Jakiel T, et al. The influence of anomalously high iron content in coal on its caloritele value determination using γ-ray[J]. Int J Appl Radiat Isot, 1999, 51(2):419.
  • 3Wenhao Gu. The influence of coal thickness change on dual-energyγ-ray ash gauge reading[J]. Int J Appl Radiat Isot, 1998, 49(12):1633.