本文分析了校准方程的关系 ,提出对于互易的测试夹具 ,使用一个传输标准得到的四个线性方程可以同时用于校准计算 .在这个关系的基础上 ,讨论了TSM(thru short match)和TRL(thru reflect line)方法中的方程选择 .实验和分析表明不同的选择会导致不同精度的结果 ,校准精度可以通过利用已建立的关系和合适地选择方程得以提高 .
The relation of calibration equations is investigated. It is shown that for the reciprocal test fixtures, the four equations obtained from the measurement with a transmission standard can be used simultaneously in the calculation. Choices of the equations in the thru-short-match (TSM) and thru-reflect-line (TRL) methods are discussed. Experimental results show that the different choice of equations will lead to different solutions, and the calibration accuracy can be improved by utilizing the established relation of the calibration equations and properly choosing calibration equations. The proposed theory can be applied to the thru-open-match (TOM) and line-reflect-line (LRL) methods.
出处
《电子学报》
EI
CAS
CSCD
北大核心
2003年第5期714-716,共3页
Acta Electronica Sinica
基金
国家重点基础研究发展规划 (No G2 0 0 0 0 3660 1 )
国家杰出青年科学基金 (No 6982 51 0 9)