临界不连续电流模式功率因数校正电路设计 被引量:4

Design of PFC Circuit Under Critical Discontinuous Current Mode
下载PDF
导出
摘要 研究了电压型和电流型临界不连续电流模式的功率因数校正电路。采用MC332 6 0设计的 5 0 0WAC/DC变换器可以适应 90~ 2 6 5V电压变化范围 ,功率因数在 0 . The critical discontinuous current mode power factor correction circuit has been studied. The control methods include voltage and current mode control. The 500W PFC circuit using MC33260 can adapt the universal voltage range of 90~265V,and the power factor of the circuit can arrive 0.98.
机构地区 华中科技大学
出处 《电力电子技术》 CSCD 北大核心 2003年第3期55-57,共3页 Power Electronics
关键词 功率因数/校正 临界不连续电流导通模式 power factor correction, critical discontinuous current mode
  • 相关文献

同被引文献12

  • 1倪海东.绿色紧凑型功率因数控制器MC33260[J].电源世界,2004(11):49-55. 被引量:1
  • 2Ben-Yaakov, Zeev Gaaton. A Unified Model of Current Feedback in Switch Mode Converters. IEEE ISCAS' 92 [J]. 1992, 4: 1891-1894.
  • 3Erickson R W, Maksimovic D. Fundamentals of Power Electronics, 2nd ed [M]. Dordrecht, The Netherlands: Kluwer, 2001.
  • 4Endo H, et al. A High Power Factor Buck Converter[C]// IEEE PESC Records, 1992 : 1017 1076.
  • 5Lo Y K, et al. Control without Current Sensing for Unity-pow- er-factor Switching-mode Rectifier[C]//Proc. of IPEM C' 94, Beijing, 1994 .. 957-962.
  • 6Peres A,et al. ZATA Converter Applied in Power Factor (;or rection[C]//IEEE PESC Records, 1994 .. 1152-1157.
  • 7.lain P. K. et al. Self-Started Voltage-source Series-resonant Converter for High-power Induction Heating and Melting Ap plication[J]. IEEE Trans. Ind. Applicat, 1998,34(3):518-524.
  • 8Atsushi Okuno et al. Feasible Development of Soft-switched SIT Innerter with Load-adaptive Frequency tracking Control Scheme for Induction Heating[J]. IEEE Trans Ind. Applicat, 1998,34(4):718.
  • 9陈果,杜维玲,王桂莲.基于MC33260的临界导电模式PFC的建模与仿真[J].通信电源术,2012,5:ll-14.
  • 10刘健,杨旭,王兆安,严百平.单位功率因数单相开关变换器的输出电压纹波[J].电力电子技术,1999,33(4):1-4. 被引量:12