摘要
采用厌氧 -缺氧 -好氧 ( AA/O法 )处理高浓度焦化酚氰废水 ,效果好 ,解决了传统生化处理法处理酚氰废水氨氮、 COD超标排放问题 ,出水水质符合 GB1 3 45 6— 1 992二级标准。
A better effects on the wasterwater treatment of coking plant which contains high concentration of phenol / cyanogen with the anaerobic /airless / aerobic (AA/O) process was introduced in this papers A older problem on wasterwater treatment of any coking plant which the treated wasterwater by tradition biochemical (A/O) process cannot conform with the GB13456-1992 standard on the content of phenol / cyanogen was resolved by the AA/O process The treated wasterwater can conform with second class of the standard
出处
《湖南冶金》
2003年第3期39-43,共5页
Hunan Metallurgy