摘要
针对目前水资源短缺状况,以齐鲁石化热电厂为例提出了利用生活污水,养鱼场排水、锅炉排污水以及化学反洗水作循环冷却水补充水的优化方案,并就废水回用方案的实施及运行中发现的问题进行了分析与探讨。
Aiming at the water resour ce shortage,using domesticsewage,discharged water from fishpond,emitled water from boiler and chemical was hed water as supplement water for circulated cooling water is proposed.The probl ems existed in practice and running of the system are analyzed.
出处
《电力环境保护》
2003年第2期40-42,共3页
Electric Power Environmental Protection
关键词
热电厂
废水
回用
thermal power plant
waste water
reuse