摘要 目的 为股骨远端粉碎性骨折设计新的内固定方法 ,从生物力学角度提供其科学依据 ,以解决复位困难、固定不牢及内外翻等畸形和并发症。方法 选用 10例新鲜成人尸体股骨 ,在髁上 -髁间截骨造成粉碎性骨折模型 ,用钢板与聚乙烯板双板组合固定 (简称双板固定 ) ,对照组采用传统的单侧钢板固定 (简称单板固定 ) ,分别进行压缩、弯曲、扭转刚度试验和双板固定屈服试验。结果 双板固定组的抗弯曲、抗扭转能力较单板固定组显著增强 (P <0 0 1)。双板固定强度试验 ,其承受轴向载荷可达 115 4 0N ,前、后、内、外弯曲载荷分别可达 70 0、10 82、5 93、10 10N。结论 双板固定股骨远端粉碎性骨折可维持碎骨块解剖复位、增强骨折内固定的稳定性和牢固性 。 Objective To develop a new method of internal fixation for comminuted fractures of distal femur,and to offer a guide for management of these injuries based on biomechanical studies. Methods 10 fresh adult femurs of cadavers were similarly made into the models of supracondylar intercondylar fractures. Double plating was performed with a steel plate combined with a polyethylene plate with the conventional sigle plating as control.The biomechanic tests (compression,bending,torsion) were performed and comparatively evaluated. Results Bending and torsion tests showed that the double plating group were much stronger ( P <0 01) than the sigle plating group in anti bending and anti torsion.During the tests of loading, the double plating group failed at a mean peak load of 11 540 N in axial compression, 700 N in anterior bending, 1 082 N in posterior bending,593 N in medial bending,and 1 010 N in lateral bending. Conclusion Double plating is an excellent technique for severe comminuted fractures of the distal femur,which provide anatomic reduction and rigid fixation so that early mobilization and weight bearing are allowed.
出处 《临床骨科杂志》 2003年第2期102-105,共4页 Journal of Clinical Orthopaedics
关键词 股骨骨折 骨折 粉碎性 骨折固定术 生物力学 femoral fractures fractures,comminuted fracture fixation, internal biomechanics
  • 相关文献

参考文献8

  • 1戴闽,戴戎,裘世静.应力松弛接骨板对骨改建影响的实验研究[J].中华外科杂志,1995,33(11):698-700. 被引量:7
  • 2周东生,王伯珉,王鲁博,许士宏,李连欣,王莆.GSH钉治疗股骨髁部骨折[J].中国矫形外科杂志,2002,9(7):652-654. 被引量:19
  • 3梁兴斌,钟永茂,袁跃华.逆行交锁髓内钉治疗股骨髁部C型骨折[J].中国矫形外科杂志,2002,9(7):650-651. 被引量:19
  • 4Do Minguez I, More RE, More JA et al. Antegraded nailimg for fractures of the distal femur[J]. Clin Orthop,1998; (350) :74-79.
  • 5Sanders R,Swiontkowski M,Rosen H et al. Double-plating of comminuted, unstable fractures of the distal part of the femur[J]. J Bone Joint Surg Am, 1991 ;73 (3) :341- 346.
  • 6Merchan ECR, Maestu PR, Blanco RP. Blade-plating of closed displaced supracondylar fractures of the distal femur with the AO system[J]. J Trauma,1992;32(2):174-181.
  • 7Shewring DJ, Meggitt BF. Fractures of the distal femur treated with the AO dynamic condylar screw[ J]. J Bone Joint Surg Br, 1992;74(1):122-125.
  • 8Muller ME. Lessons of 30 years of total hip arthroplasty[ J]. Clin Orthop, 1992; (274) :12- 17.

二级参考文献5

共引文献39

同被引文献107

引证文献11

二级引证文献66

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部