摘要 在实验测量取得了触发脉冲波形和间隙开关动作特性等参数的基础上 ,分别对由两个间隙开关及三个间隙开关组成并联系统的大电流冲击放电装置进行了同步运行实验 .对系统的同步状况进行了测量和分析 ,研究了工作电压和触发电压对系统同步的影响 。 In this paper, the operation experimental research of synchronous operation on high current impulse discharge devices with parallel system composed of two gap switches or three gap switches is conducted on the basis of obtained wave form of trigger pulse and the actuation characteristics of gap switches. The synchronous state of the system is measured and analyzed and the influence of working and triggering voltage on the synchronigation of the system is also studied. A new method to assess the synchronous status is put forward by using the ratio of the measured value and the theoretic value of impulse current amplitude.
出处 《沈阳工业学院学报》 2003年第2期12-15,共4页 Journal of Shenyang Institute of Technology
  • 相关文献

参考文献2

  • 1王友青 唐宏 马乃祥.高压高陡度脉冲发生器及测量系统[z](全国高压年会)[Z].,1988..
  • 2Turman B N. A 100TW pulsed power driver for the inertial confinement fusion program, IEEE Proceedings of thc 5th pulsed power[C], Arilington VA. P. 155,1985.