摘要
介绍了PG9171E燃气轮机调试运行过程中出现的燃油系统振荡故障的处理过程。对该故障可能产生的原因进行了分析 ,指出MARKV燃油伺服控制常数的不匹配是本次故障的根本原因 。
The oscilation fault of fuel-oil system in the course of commissioning operation for a PG 9171E type gas turbine has been presented in detail. Analysis of all possible causes leading to the said fault has been made, pointing out the mismatching of parameters of the MARKV servo-control system of the said fuel oil was the basic reason of the abovementioned fault, and the final result of parameters' optimization having been given.
出处
《热力发电》
CAS
北大核心
2003年第6期45-46,52,共3页
Thermal Power Generation