手术床是大型影像设备DSA (digital subtraction angiography)的重要部件,它的故障比其它部件多。本文讨论了手术床的移动故障,也分析了在CPU 控制下机械部件的维修方法。
Operating table is important part of large imaging equipment DSA (digital subtraction angiography). Its troubles are more than others. This paper discussed the move trouble of operating table., and also Analyzed the maintenance method of machine part under CPU Controlling.