摘要
本文给出了自给能γ剂量计探头在γ射线照射下积累电荷的测量结果,讨论了电容比和方向性对自给能γ剂量计探头的影响以及探头的饱和点。
Chargedeposited densities of selfpowered detect or s irradiated by γray are measured, and some experimental results are give n. The saturation point and the influence of capacitance ratios and incident angles upon selfpowered detectors are discussed.
出处
《原子能科学技术》
EI
CAS
CSCD
2003年第3期286-288,共3页
Atomic Energy Science and Technology
基金
国家自然科学基金资助项目(1860117)