期刊文献+

50MW机组推力轴承的改进及运用 被引量:1

Improvement and Application of Thrust Bearing in 50MW Turbine-Ge nerator Unit
下载PDF
导出
摘要  针对现役50MW机组推力轴承瓦温偏高现状,通过分析传统推力轴承结构,找出了轴承偏载及瓦温偏高的原因。从改进结构设计着手,推出了新型的LEG(LeadingEdgeGroove)推力轴承,并对LEG推力轴承和传统推力轴承性能进行了比较分析。通过LEG推力轴承和传统推力轴承的现场应用实例比较,证实了LEG推力轴承性能的优越性。 Taking into consideration the higher temperature o n the thrust bearing pad surface for existing 50MW turbine-generator unit, the deviant reason of load and temperature on the thrust bearing pad surface have be en found out by analyzing the structure of the conventional thrust bearing. Star ting with structural design modification , a new LEG thrust bearing is designed, and moreover, the performance of the LEG thrust bearing is compared to that of the conventional thrust bearing in field application. The fact shows that the LE G thrust bearing has its performance advantage.
出处 《热力透平》 2003年第2期117-120,123,共5页 Thermal Turbine
关键词 50MW机组 推力轴承 瓦面温度 改进设计 汽轮机 LEG 浸润式轴承 LEG thrust bearing pad surface temperature improve d design application
  • 相关文献

参考文献3

  • 1.火力发电设备技术手册[M].机械工业出版社,1999年6月..
  • 2张志华 等.300MW、600MW火电机组国产化推力轴承试验研究[A]..国家重大技术装备科技攻关项目鉴定文件之二[C].,1992年6月..
  • 3ANDREWM MIKULA. Evaluating Tilting-Pad Thrust Bearing Operating Temperatures [ J ]. ASLE, 1985,29(2) :173-178.