期刊文献+

几种换热管强化传热性能实验分析与比较 被引量:28

Experiment Analysis and Comparison to the Intensify Transmit Heat Function of Several Kinds of Exchanger Tube
下载PDF
导出
摘要 选择光管、螺纹管、波纹管换热器进行传热性能实验。实验结果表明波纹管换热器的总传热系数最大 ,其次是螺纹管 ,最小是光管 ;螺纹管的管内 (热侧 )压降最大 ,其次是波纹管 ,最小是光管 ;管外 (冷侧 )三种管型压降相差不大。 According to the intensify transmit heat theory,several kinds of the exchanger tube (light tube, whorl tube,ripple tube) is chosed to do the experiment of the intensify transmit heat function.The results indicated:the total transmit heat coefficient of ripple tube is the largest,then the whorl tube and the third the light tube;the pressure drop in the whorl tube (hot side) is the largest, then the ripple tube and the third the light tube;the pressure drop out of the tube (cold side) has hardly any difference finally.The triple tubes for the tube type of the reform exchanger is determined.
出处 《流体机械》 CSCD 2003年第6期7-10,共4页 Fluid Machinery
关键词 波纹管 螺纹管 光管 换热器 传热性能 triple tube whorl tube light tube exchanger transmit heat function
  • 相关文献

参考文献6

二级参考文献27

共引文献59

同被引文献118

引证文献28

二级引证文献129

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部