期刊文献+

电容式微机械加速度计测量范围上限设计 被引量:1

Design of upper limit of measurement range on capacitive micromachined acceler ometer
下载PDF
导出
摘要 测量范围上限设计一直是高gn值微惯性引信研制的一个难题,对差动电容式微加速度计各参数对量程的本质影响及其相互关系进行了研究,理论分析和计算机仿真结果表明:按同一比例尽量减小封装间隙和电极面积,使得受限于临界偏压的外加偏压取值刚好能提供需要的量程,同时使用质量块减薄和打孔并用的方法来提高最大量程,所设计出的加速度计可具有70gn以上量程。 Design of upper limit of measurement range is alwa ys a difficult problem in the development of micro inertial fuze with high gn value.The essential influences of the parameters of diffe rential capacitive microaccelerometer on the measurement and the mutual relati ons are studied.The results of theoretical analysis and computer simulation show : the encapsulation gap and the electrode area should be as possible as reduced by the same proportion,the applied bias voltage value restricted to the critical voltage should just meet the needs of the measurement,and the maximum measureme nt range is increased by the reduction of thickness and the holes in the sensiti ve mass,so measurement range of the designed accelerometer will be higher than 70?gn.
出处 《传感器技术》 CSCD 北大核心 2003年第6期62-64,共3页 Journal of Transducer Technology
基金 国防"九五"重点预研项目
关键词 微机械加速度计 测量范围上限 差动电容结构 参数 微电子机械系统 最大量程设计 micromachined accelerometer uppe r limit of measurement range differential capacitive structure parameter
  • 相关文献

参考文献2

二级参考文献8

  • 1郭秀中.惯导系统陀螺仪理论[M].北京:国防工业出版社,1996.4-5.
  • 2朱绍箕.从西欧三国考察看惯性技术发展[J].飞航导弹,1999,(1):34-38.
  • 3胡平华 杜祖良 等.从第二届北京国际惯性技术会议看惯性技术发展动向[J].飞航导弹,1999,(3):46-50.
  • 4毛刚,导航,1999年,4期,8页
  • 5胡平华,飞航导弹,1999年,3期,46页
  • 6朱绍箕,飞航导弹,1999年,1期,34页
  • 7郭秀中,惯导系统陀螺仪理论,1996年,29页
  • 8毛刚,顾启泰.微型惯性测量组合发展综述[J].导航,1999,35(2):8-14. 被引量:7

共引文献23

同被引文献2

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部