摘要 随着超净化实验室条件的完善以及多接收同位素质谱技术的成熟 ,铅同位素双稀释法倍受关注。用双稀释法测定铅同位素比值的方法原理 ,以及 2 0 4 Pb- 2 0 7Pb双稀释剂的配制和标定方法。通过对标准物质 NBS981和地质样品的分析测定 ,表明用双稀释法测定铅同位素比值 ,可以有效校正由质谱分析造成的同位素分馏效应 ,从而提高分析结果的精度和准确度。 Pb isotope analysis of using a 204Pb- 207Pb double thinner has drawn much attention with the ultra-clean chemical laboratory and multi-collector mass spectrometry. The principles of Pb isotope analysis of using a double thinner are introduced, and the method of compound and determination of 204Pb- 207Pb double thinner are presented. The Pb isotopic analyses for standard NBS981 and geological samples suggest that isotopic fractionation caused by mass spectrometry can be corrected effectively by using a 204Pb- 207Pb double thinner and thus improve the precision and accuracy of the analysis.
作者 王林森 张利
出处 《矿物岩石》 CAS CSCD 北大核心 2003年第2期44-48,共5页 Mineralogy and Petrology
基金 国土资源部壳幔开放实验室基金
关键词 双稀释法 地质样品 铅同位素 标定方法 质谱分析 同位素分馏效应 精度 204Pb-207Pb double thinner Pb isotopic analysis isotopic fractionation
  • 相关文献

参考文献14

  • 1Compston W,Oversby V M. Lead isotopic analysis Using a double-spike[J]. J Geophys Res, 1969,74:4338-4348.
  • 2Woodhead J D,Volk F,Mccoloch M T. Routine lead isotope determinations using a ^207Pb-^204Pb double spike: a long-term assessment of analytical precision and accuracy [J ]. Analyst, 1995,120 : 35-39.
  • 3Foelling P G,Zartman R E,Frimmel H E. A novel approach to double-spike Pb-Pn dating of carbonate rocks ; examples from Neoproterozoic sequences in Southern Africa[J]. Chemical Geology,2000,171:1-2, 97-122.
  • 4Thirlwall M F. Inter-laboratory and other errors in Pb isotope analyses investigated using a ^207Pb-^204Pb double spike[J]. Chemical Geology,2000,163 : 1-4, 299-322.
  • 5Galer. Stephen. J. G. Optimal double and triple spiking for, high precision lead isotopic measurement [J]. Chemical Geology, 1999,157 : 3-4,255-274.
  • 6Powell R,Woodhead j,Hergt J. Uncertainties on lead isotope analyses: deconvolution in the double-spike method[J]. Chemical Geology,1998,148:1-2, 95-104.
  • 7Woodhead J D,Hergt J M. Application of the "double spike"technique to Pb-isotope geocnronology[J] .Chemical Geology, 1997,138:3-4,311-321.
  • 8Cumming G L. Prapogation of experimental error in lead isotope ratio measurements using the double spike method[J]. Chem Geol, 1973,11,157-165.
  • 9Boeelrijk N A M.A general formula for double isotope dilution analysis[J]. Chem Geol,1968,3(4),323-325.
  • 10Cooper J A,Reynolds P H,Richards J H. Double spike calibration of the Broken Hill standard lead, Earth Planet[J]. Sci Lett, 1969,6467-478.

同被引文献67

  • 1郭庆军,杨卫东,余娅.铅同位素“双稀释剂”同位素定年法计算方法研究[J].矿物岩石地球化学通报,2000,19(3):193-196. 被引量:3
  • 2何学贤,唐索寒,朱祥坤,王进辉.多接收器等离子体质谱(MC-ICPMS)高精度测定Nd同位素方法[J].地球学报,2007,28(4):405-410. 被引量:43
  • 3Dodson M H. A theoretical study of the use of internal standards for precise isotopic analysis by the surface ionization technique. Part I . General first order algebraic solutions [ J ]. Journal of Scientific Ir~truments, 1963, 40 : 289 - 295.
  • 4Compston W, Oversby V M. Lead isotopic analysis using a double spike [ J ]ournal of Geophysical Research, 1969, 74(17) : 4338 -4348.
  • 5Cooper J A, Reynolds P H, Richards J H. Double spike calibration of the Broken Hill standard lead ~ J ]. Earth and Planetary Science Letters, 1969, 6 : 467 - 478.
  • 6Galer S J G. Optimal double and triple spiking for high precision lead isotopic measurement [ J ]. Chemical Geology, 1999, 157 : 255 - 274.
  • 7Hamelin B, Manhs G, Albarde F, Alligre C J. Precise lead isotope measurements by the double spike technique: A reconsideration [ J ]. C, eochimica et Cosmochimica Acta, 1985, 49 : 173 - 182.
  • 8Powell R, Woodhead J, Hergt J. Uncertainties on lead isotope analyses : Deconvolution in the double spike method [J]. Chemical Geology, 1998, 148 : 95 - 104.
  • 9Thirlwall M F. Muhicollector ICP-MS analysis of Pb isotopes using a 2^207vpb-^204 Pb double spike demonstrates up to 4000 ppm/amu systematic errors in Tl-normalization [ J]. Chemical Geology,2002, 184 : 255 - 279.
  • 10Baker J, Peate D, Waight T, Meyzen C. Pb isotopic analysis of standards and samples using a ^207pb-^204Pb double spike and thallium to correct for mass bias with a double-focusing MC-ICP-MS [ J ]. Chemical Geology, 2004,211:275 - 303.

引证文献4

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部