摘要 目的研究基于PC机的虚拟内窥系统中的自动导航方法。方法首先设计了一种基于位编码和坐标变换的快速 3D细化算法来提高提取器官骨架的运算速度 ;然后采用 2次跟踪技术裁剪骨架分支得到所需的导航路径 ;最后提出一种 3遍 3次Bezier平滑导航路径算法和Bezier插值算法 ,使导航路径至少能达到C1 连续且较为平坦 ,并以平滑的导航路径上的点控制虚拟摄像机位置 ,以对应点处的切线 (一阶导数 )控制虚拟摄像机方向。结果对经过分割后获得的人体气管体数据进行自动导航实验 ,结果表明 ,在自动导航中虚拟摄像机能保持远离气管内壁 ,而且相邻帧之间过渡比较平滑 ,能产生效果很好的自动导航动画。结论方法实现简单 。 Objective To explore the method of automatic navigation for PC based virtual endoscope system. Method A 3D thinning algorithm based on bit encoding and coordinates transform was designed to speed up the calculation of extracting the skeleton. The small branches of the skeleton were trimmed using two pass tracking technique. Then, the central line was smoothed by using tri pass cubic Bezier smoothing method. A plainer central line was obtained by using aforementioned algorithms and the resulted line had C 1 continuity at least. The virtual camera would move along this smoothed navigation path point by point and the camera direction followed the tangent of the central line. Result Automatic navigation experiments were carried out with the volume data of segmented human trachea and the results showed that the camera was kept off the inner wall of the trachea during the automatic navigation and the animation transition was gentle and smooth. Conclusion The proposed algorithms are simple to realize and meet the requirements of virtual endoscope in clinic.
出处 《航天医学与医学工程》 CAS CSCD 北大核心 2003年第3期201-205,共5页 Space Medicine & Medical Engineering
基金 安徽省自然科学基金 ( 0 10 42 2 0 2 )
关键词 虚拟内窥镜 算法 3D细化 自动导航 virtual endoscope agorithm 3 D thinning automatic navigation
  • 相关文献

参考文献1

二级参考文献2

共引文献4

同被引文献22

  • 1申皓,唐泽圣,唐龙.分支结构中的虚拟内窥技术[J].系统仿真学报,2004,16(11):2456-2458. 被引量:4
  • 2彭延军,王元红,石教英,郑永果.虚拟内窥镜关键技术研究[J].计算机应用研究,2005,22(5):37-39. 被引量:2
  • 3王怡,周明全,耿国华.虚拟内窥镜中心路径抽取技术[J].西北大学学报(自然科学版),2005,35(6):695-698. 被引量:6
  • 4崔宁,张彩明,刘毅.应用于虚拟内窥镜系统的拓扑细化算法的优化[J].系统仿真学报,2006,18(10):2856-2858. 被引量:5
  • 5Chen D Q,Li B,Roche P,et al.Feasibility studies of virtual laryngoscopy by CT and MRI from data acquisition,image segmentation,to interactive visualization[J].IEEE Transactions on Nuclear Science, 2001,48 ( 1 ) :51-57.
  • 6Wann M,LI W,Kreeger K,et al.3D Virtual Colonoscopy with Real-time volume rendering[C/OL].SPIE Symposium on Medical Imaging, 2000.http ://www.mil.sunysb.edu/miel/papers/SPIE_2000 Mwan VC.pdf.
  • 7Deschamps T,Letang J M,Verdonek B,et al.Automatic constructinion of minimal paths in 3D images:An application to virtual en doscopy[C]//Proceedings of Computer Assisted Radiology and Surgery, 1999.
  • 8Deschamps T,Cohen L.Fast extraction of minimal paths in 3D images and applications to virtual endoscopy[J].Medical Image Analysis, 2001,5(4):281-299.
  • 9Vilanova A,Konig A,Groller E.VirEn:A virtual endoscopy system[J]. Machine Graphics and Vision, 1999,8(3 ) : 469-487.
  • 10Wahle A,Olszewski M E,Sonka M.Interactive virtual endoscopy in coronary arteries based on multimodality fusion[J].IEEE Transactions on Medlcal Imaging, 2004,23 ( 11 ) : 1391-1403.

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部