期刊文献+

新型压电摩擦阻尼器本构模型的分析 被引量:4

Property analysis of a piezoelectric friction damper
下载PDF
导出
摘要 随着振动控制技术的发展 ,半主动控制引起工程界人士的广泛关注 .可控摩擦阻尼器作为一种有效的半主动控制装置获得了广泛的研究和应用 .本文正是在着力改进现有可控摩擦阻尼器的基础上 ,设计了压电摩擦阻尼器 PALL支撑 ,为结构振动的控制提供了一种全新的选择 .文中采用了 ANSYS软件的有限元分析方法 ,对压电摩擦阻尼器进行了性能模拟试验 ,研究了其在各级电压下的摩擦耗能特性 ,在此基础上我们给出了压电摩擦阻尼器 With the developrment of technology in structural vibration control, semi active control methods have attracted more and more attention from engineering society. In this paper, a new semi active control system, the piezoelectric friction damper PALL (PFDP) brace' is designed, as an alternative for structural vibration control purpose. In the analysis of the PFDP brace's damping property, finite element analysis program ANSYS is put to use. From this analysis, the damping property at different voltage is derived. And a bilinear damping model with voltage parameter is developed.
出处 《西安建筑科技大学学报(自然科学版)》 CSCD 2003年第2期123-126,共4页 Journal of Xi'an University of Architecture & Technology(Natural Science Edition)
基金 陕西省教育厅专项基金资助项目 ( 0 2 JK12 0 )
关键词 压电摩擦阻尼器 性能分析 半主动控制 piezoelectric friction damper property analysis semi active control
  • 相关文献

参考文献3

二级参考文献6

共引文献38

同被引文献44

  • 1吕西林,叶骅.结构主动控制和混合控制技术的新发展[J].世界地震工程,1997,13(2):21-29. 被引量:10
  • 2杨浩.[D].沈阳建筑工程学院,2003.
  • 3STRANB F K. Development of a piezoelectric actuator for trailing edge flap control of full scale rotor blades[Jl. Smart Material and Structure, 2001, 10(1) : 25 - 34.
  • 4YAO J P T. Concept of structural control [ J ]. Journal of Structure Division, 1972, 98: 1567- 1573.
  • 5KAMADA T, FUJITA T, HATAYAMA T. Active vibration control of frame structures with smart structures using piezoelectric actuators (Vibration control by control of bending moments of columns) [J]. Smart Material and Structure, 1997, (6) : 448- 456.
  • 6KAMADA T, FUJITA T, HATAYAMA T, ARIKABE T. Active vibration control of flexural-shear type frame structures with smart structures using piezoelectric actuators [ J ]. Smart Material and Structures, 1998, (7) : 479 - 488.
  • 7SONG Gangbing. Active vibration control of a space truss using PZT stack actuator [ J ]. American Society of Mechanical Engineers, Aerospace Division, 1999, 59: 263-268.
  • 8FUJITA T. Active microvibration control of precision manufacturing factories with smart structure using piezoelectric actuators[ A].Proceedings of the International Society for Optimal Engineering[C]. Newport Beach, CA, USA, 2001, 4330: 449-459.
  • 9HAN Sangjun. Active/passive seismic control of structures[ D].The Catholic University of America, 2002.
  • 10KITAGAWA Y. Characteristics of piezoelectric damper in smart structural system [A]. Proceedings of the International Society for Optimal Engineering[C]. San Diego, CA, USA, 2003,5057: 197- 206.