期刊文献+

六分钟步行实验心率和心力变化测试及临床研究 被引量:5

A Study on 6-Minute Walk Test Incorporating Cardiac Contractility And Heart Rate Change Measurements
下载PDF
导出
摘要 目的:研究在6min步行试验中加入心力变化趋势和心率变化趋势测试和评估方法及其临床应用。方法:心血管病患者25人和无心血管病者25人自愿加入该对照研究。完成6min步行试验运动后S1幅值对安静时S1幅值增加的相应倍数定义为心力变化趋势CCCT(6')。结果:两组受试者6min步行试验中步行的总距离、心力和心率数据间都有非常显著的差异。结论:提示该项研究所用方法能克服单纯用6min步行试验中步行距离来评估心功能所存在的问题,具有无创、安全、简便、快速、费用低、可重复采用和客观等特点,能用于病室和门诊测评心脏储备。 Objective:Studying6-minite walk test incorporating cardiac contractility change trend and heart rate change trend measurements and its clinical applications.Methods:25patients with cardiovascular diseases and25subjects without cardiovascular diseases were included this study.Signals of cardiac cycle and cardiac contractility were si-multaneously collected and recorded before and immediately after6-minite walk test.The total distance during6-minite walk test also recorded.The increase of the amplitude of the first heart sound after6-minite walk test,with respect to the amplitude of the first heart sound recorded at rest was defined as cardiac contractility change trend(CCCT(6')).Results:It was found that there was a very significant difference between the two sets of data of walking distance,cardiac contractility change trend,and heart rate change trend.Conclusion:The results show that the method of6-minite walk test incorporating cardiac contractility change trend and heart rate change trend measurements can be used for evaluating cardiac function,with the advantages of being noninvasive,safe,convenient,inexpensive,rapid,simple,objective,repeatable,and able to be performed at the bedside,in the outpatient department.
出处 《医疗卫生装备》 CAS 2003年第6期16-18,共3页 Chinese Medical Equipment Journal
基金 国家自然科学基金(30070211)部分资助
关键词 六分钟步行实验 心功能评估 心率变化趋势 心力变化趋势 minute walk test Cardiac contractility change trend Heart rate change trend Cardiac reserve
  • 相关文献

参考文献10

  • 1肖守中,周书先,周继英,蒋义淑,詹直夫,孙小波.心力监护仪在心音图运动试验和颈动脉图运动试验中的应用[J].仪器仪表学报,2000,21(z1). 被引量:16
  • 2Bittner V, Weiner DH, Yusuf S, et al.Prediction of mortality and morbidity with a 6-minute walk test in patients with left ventric ular dysfunction[J]. JAMA,1993,270:I702.
  • 3Zugcka C, KrUgem C, DUrra S, et al. Is the 6-minute walk test a reliable substitute for peak oxygen uptake in patients with dilated cardiomyopathy?[J]European Heart Journal,2000,21:540-549.
  • 4Sum-Kin Leung, Chu-Pak Lau, Cathy Tse-Fun Lam,et al. Auto matic optimization of resting and exercise atrioventricular interval using a peak endocardial acceleration sensor, validation with Doppler echocardiography and direct cardiac output measurements[J]. Pace ,2000,23[Pt.Ⅱ]:1762-1766.
  • 5Hansen PB,Luisada AA,et al. Phonocardiography as a Monitor of Cardiac Performance During Anesthesia[J]. Anesth Analg,1989,68:385-387.
  • 6L. G. Durand, Y. E. Langlois, T. Lanthier. Spectral analysis and acoustic transmission of mitral and aortic valve closure sounds in dogs, Part 1: Modelling the heart/thorax acoustic system[J]. Med.& Biol. & Eng. & Comput.,1990,28:269-286.
  • 7Cao Zehan, Xiao Shouzhong, et al. The Quantitative Analysis Ap proach for a heart Sound Information System[C]. In IEEE EMBS'98 Proceedings, Hong Kong, 1998.1622-1624.
  • 8Xiao Shouzhong, Cao Zehan, Zhou Shiyong, et al. An Application of Phonocardiogram Exercise Test in Evaluation of Cardiac Reverse[C]. In IEEE EMBS'98 Satellite Conference Proceedings, Beijing, 1998.82-83.
  • 9Xiao Yihua, Xiao Shouzhong, Cao Zehan, et al. A study on phonocardiogram exercise test[J]. IEEE Engineering in Medicine and Biology Magazine,1999,18(4):111-l15.
  • 10Xiao Shouzhong, Carl Shaoxi, Liu Guochuan. Studying the Signifi cance of Cardiac Contractility Variability[J]. IEEE Engineering in Medicine and Biology,2000,19(3):81-83.

二级参考文献9

  • 11,The Criteria Committee of the New York Heart Associa-tion. Nomenclature and Criteria for Diagnosis of Diseases of the Heart and Great Vessels. 7th ed. Boston:Little, Brown and Company 1973.
  • 22,L. Campeau. Grading of angina pectoris. Circulation. 1976; 54:522-523.
  • 33,HANSEN PB, LUISADA AA et, al. Phonocardiography as a Monitor of Cardiac Performance During Anesthesia: Anesth Analg 1989, 68:385~387.
  • 44,J.C.Wood, D.T. Barry, Time-Frequency Analysis of the First Heart Sound, IEEE Eng. in Med. & Boilo., March/April 1995, 14(2):144~151.
  • 55,L.G.Durand, Y.E.Langlois, T.Lanthier, Spectral analysis and acoustic transmission of mitral and aortic valve closure sounds in dogs, Part 1:Modelling the heart/thorax acoustic system, Med. & Biol.& Eng.& Comput., 269—286,1990,28:269—286.
  • 66,M.L.Rice and D.J.Doyle. Comparison of Phonocardiographic Monitoring Location. IEEE EBMC'95 CD-ROM Proceedings, 3.1.4.12.
  • 77,Cao Zehan, Xiao Shouzhong, et al. The Quantitative Analysis Approach for a heart Sound Information System. In IEEE EMBS'98 Proceedings, Hong Kong, 1998:1622~1624.
  • 88,Xiao Shouzhong, Cao Zehan, Zhou Shiyong et al. An application of Phonocardiogram Exercise Test in Evaluation of Cardiac Reverse. In IEEE EMBS'98 Satellite Conference Proceedings, Beijing, 1998,82~83.
  • 99,Xiao Yihua, Xiao Shouzhong, Cao Zehan, Zhou Shiyong, Pei Jianhua.. A study on phonocardiogram exercise test. IEEE Engineering in Medicine and Biology Magazine, 1999, 18(4):111~115.

共引文献15