期刊文献+

微波消化-ICP-MS法测定尿样中15种金属元素 被引量:6

Determination of Fifteen Trace Elements in Human Urine by Microwave Digestion Inductively Coupled Plasma Mass Spectrometry
下载PDF
导出
摘要 采用微波消化 电感耦合等离子体质谱法测定尿样中的15种金属元素,方法回收率81%~107%,相对标准偏差为1.14%~6.71%,方法具有快速、简便、灵敏、准确的优点,对探索微量元素与健康的关系具有十分重要的意义. A method for the determination of fifteen trace elements in human urine by microwave digestion inductively coupled plasma mass spectrometry is reported. The detection limits of the method are suitable to determine human urine samples. The recoveries were from 81 % to 107 %. The relative standard deviations were from 1.14 % to 6.71 %. The method is rapid, simple, sensitive and accurate. It can be used to evaluate the relationship between trace elements and health problems.
出处 《分析测试技术与仪器》 CAS 2003年第2期98-100,共3页 Analysis and Testing Technology and Instruments
关键词 微波消化 ICP MS 测定 尿样 金属元素 电感耦合等离子体质谱 微量元素 健康 microwave digestion inductively coupled plasma mass spectrometry trace elements urine