PRK、LASIK术后非接触眼压测量值的准确性 被引量:6

Accuracy of noncontact tonometry after PRK and LASIK
下载PDF
导出
摘要 目的 :评估准分子激光屈光性角膜切削术 (PRK)和准分子激光原位角膜磨镶术 (LASIK)后非接触眼压 (NCT)测量值的准确性。方法 :对 5 5例 (10 9只眼 )行PRK和 5 7例(113只眼 )行LASIK的近视患者进行回顾性分析 ,手术前、后采用非接触眼压计测量患者的眼压 ,并测量角膜厚度和角膜曲率 ,进行统计学分析。术后随访时间 >1年 ,停用激素至少半年以上。结果 :PRK和LASIK术后NCT测量值都低于术前 ,分别下降 (3.6 7± 1.6 5 )mmHg和 (5 .11± 1.5 1)mmHg ,差异有非常显著意义 (P <0 .0 0 1)。PRK和LASIK术前眼压测量值与角膜厚度均呈高度正相关 (P <0 .0 0 1) ;术后眼压测量值的降低与角膜厚度的减少高度正相关 (P <0 .0 5 ) ,其回归方程分别为 ^Y(手术前、后眼压差 ,mmHg) =1.36 1+0 .0 38X(手术前、后角膜厚度差 ,μm)和 ^Y =1.95 4 +0 .0 4 0X ;眼压测量下降值和角膜曲率的降低无关。结论 :PRK和LASIK术后眼压测量值均低于术前 ,角膜厚度是导致手术后眼压测量值减少的主要因素 ,且眼压测量值随角膜厚度的减少而下降。在临床工作中 ,应避免术后类固醇性青光眼因眼压测量值的下降而被漏诊。 Objective:To assess the accuracy of noncontact tonometry after PRK and LASIK.Methods:55 patients(109 eyes) who had photorefractive keratectomy(PRK) and 57 patients(113 eyes) who had laser in situ keratomileusis(LASIK) performed by the same surgeon were reviewed retrospectively. All patients had discontinued steroid use for at least 6 months postoperatively and were thus eligible for evaluation of preoperative and postoperative intraocular pressure(IOP). Corneal thickness(pachymetry) and corneal topography were evaluated.Results:Preoperative and postoperative data showed that the mean decrease in the measured IOP was(3.67±1.65)mmHg (P<0.001) after PRK and(5.11±1.51)mmHg (P<0.001) after LASIK,and pachymetry was related to IOP measurement with NCT(P<0.001). No group(PRK or LASIK) had NCT values associated with central corneal curvature values nor decreased NCT values associated with decreased corneal curvature values. Regression analyses indicated that in both groups the decreased NCT values were higher in the eyes that had thicker corneas ablated(P<0.05).Conclusion:Corneal refractive surgery changed the accuracy of the NCT,causing it to underestimate IOP. The reduction was not correlated with the flattening of the central cornea. Decreased NCT values were due to decreased corneal thickness. When evaluating IOP after surgery,this possibility should be carefully investigated.[
出处 《眼视光学杂志》 2003年第2期89-91,共3页 Chinese Journal of Optometry & Ophthalmology
基金 浙江省教育厅科技项目 (SJ990 0 10 )
关键词 准分子激光屈光性角膜切削术 准分子激光原位角膜磨镶术 眼内压 角膜厚度 近视 excimer laser photorefractive keratectomy/methods laser in situ keratomileusis/methods introcular pressure corneal thickness
  • 相关文献

参考文献10

  • 1余野,王勤美,许琛琛.LASIK前后非接触眼压计测量结果的研究[J].眼视光学杂志,1999,1(2):89-91. 被引量:14
  • 2张晓峰,潘承思,李龙标,丁洁.影响准分子激光屈光性角膜切削术后眼压的因素[J].中华眼科杂志,1998,34(5):385-387. 被引量:15
  • 3李丽,张月梅.准分子激光角膜切削术后3年临床疗效分析[J].眼视光学杂志,2002,4(2):86-89. 被引量:4
  • 4吴小影,刘双珍,黄佩刚,王平宝.准分子激光屈光性角膜切削术后眼压测量值的变化[J].中华眼科杂志,2002,38(10):603-605. 被引量:8
  • 5Chaterjee A,Shah S,Bessant DA,et al.Reduction in intraocular pressure after excimer laser photorefractive keratectomy.Correlation with pretreatment myopia.Ophthalmology,1997,104(3) :355 - 359.
  • 6Ehlers N,Bramsen T,Sperling S.Applanation tonometry and central comeal thickness.Acta Ophthalmol,1975,53(1):34-43.
  • 7Doughty MJ,Laiquzzaman M,Muller A,et al.Central comeal thickness in European (white)individuals,especially children and the elderly,and assessment of its possible importance in clinical measures of intraocular pressure.Ophthalmic Physiol Opt,2002,22(6):491-504.
  • 8Agudelo LM,Molina CA,Alvarez DL.Changes in intraocular pressure after laser in situ keratomileusis for myopia,hyperopia,and astigmatism.J Refract Surg,2002,18(4):472-474.
  • 9Rasbad KM,Laser in situ keratomileusis(LASIK)for correction of myopic.Egypt J Cataract Refract Surg,1996,2:17-29.
  • 10Zadok D,Tran DB,Twa M,et al.Pneumotonometry versus Goldmann tonometry after laser in situ keratomileusis for myopia.J Cataract Refract Surg,1999,25(10):1344-1348.

二级参考文献8

共引文献36

同被引文献32

引证文献6

二级引证文献11

相关作者