用微拉伸法测试三种牙本质粘结剂在离体后牙纵裂模式中的强度 被引量:7

Evaluation of the Microtensile Bond Strengths of Three Adhesive Systems on Vertically Fractured Molars
下载PDF
导出
摘要 目的:比较三种牙本质粘结剂在离休纵裂后牙粘结中用微拉伸法所测得的牙本质粘结剂强度。方法:选用36颗拔除的人类磨牙,随机分为3组,制备成纵折模型,舌侧牙片剖面开本质粘结树脂块,3组粘结系统分别为可乐丽、单瓶粘结剂、超强粘结剂。标本置37℃水中恒温24h后,舌侧半树脂块修整成约1.5mm厚酒杯状薄片,粘在特制的固定装置上,在万能材料试验机上以1mm/min的横梁移动速率做拉伸测试。用扫描电镜观察其断裂方式。结果:用微拉伸法所测得的三种粘结剂强度分别为:可乐丽:19.9±0.95Mpa;单瓶粘结剂:12.8±0.81Mpa;超强粘结剂:15 3±1.2MPa,经方差分析,三种粘结剂强度问均有显著差别(P<0.05)。扫描电镜观察见试件断裂均为界面破坏。结论:用微拉伸法测得的可乐丽粘结强度相对较高。 Objective: To determine the bond strengths between dentin and three adhesive systems on vertically fractured molars, by means of microtensile tests. Methods: Thirty - six extracted human molars were randomly assigned to three groups. Teeth were cut parallel to their long axis. A block composite resin was built on the longitudinal section with one of the following adhesive systems: Clearfil SE Bond and Single Bond,Super Bond C&B. All specimens were stored in 37℃ C distilled water for 24 hours.The block composite resin were trimmed into slabs of 1.5mm thick.then tested by the universal testing machine at a cross speed of 1mm/min.The fracture surfaces were examined by SEM. The results were compared using ANOVA. Results: The mean bond strength for each resin was as follows: Clearfil SE Bond, 19.9 ± 0.95Mpa; SingleBond, 12.8±0.81Mpa; Su-per Bond C&B, 15. 3±1. 2Mpa. There were significant differences among three adhesive systems(P<0. 05). All specimens were found fractured at interface.Conclusion: The microtensile bond strength of Clearfil SE Bond was the highest.
出处 《中国临床医学》 2003年第3期283-284,287,共3页 Chinese Journal of Clinical Medicine
基金 上海市卫生局科研基金 编号 200258
关键词 微拉伸法 测试 牙本质粘结剂 离体 牙纵裂 Microtensile Adhesive Vertically fracture
  • 相关文献

参考文献8

  • 1Sugaya T, Kawanami M, Noguchi H. Periodontal healing after bonding treatment of vertical root fracture. Dent Traumatol ,2001,17 : 174 - 179.
  • 2Panlo EC, Roberto R, Marcela RO. Evaluation of micro- tensih, shear and tensile tests determining the bond strengh of three adhesive systems. Dent Mater, 1998,14:394-398.
  • 3Sano H, Shono T, Sonoda H, et al. Relationship between suface area for adhesion and tensile bond strength - evaluation of a micro - tensile bond test. Dent Mater, 1994,10(7) :236-240.
  • 4Van Noort R, Noroozi S, Howard IC, et al. A critique of bond strength measurements. J Dent, 1989,17 : 61 - 67.
  • 5Suwachai P, Michael FB, Martin J, et al. The influence of crosssectional shape and surface area on microtensile bond test.Dent Mater, 1998,14:212-221.
  • 6Yoshiyama M, Sano H, Ebisu S, et al. Regional strengths of bonding agents to cervical sclerotic root dentin. J Dent Res,1996,75(6) : 1404-1413.
  • 7Fujishima A, Fujishima Y, Ferracane JL. Shear bond strength of four commercial bonding systems to CPTi. Dent Mater, 1995,11(2) :82-86.
  • 8Masaka N. Long - term observation of fractured tooth roots preserved by adhesion. Adhes Dent, 1995,13 : 156 - 170.

同被引文献69

引证文献7

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部