期刊文献+

热式复合传感器分析 被引量:2

The Analysis of Thermal Compound Sensor
下载PDF
导出
摘要 由热式复合传感器构成的测量系统可以实现气固两相流的固相质量流量测量 ,在应用中该传感器存在一定的热惯性和滞后特性。建立了热式复合传感器的数学模型 ,对模型进行了仿真 ,求出了该传感器的时间常数和滞后系数 ,并得出了环境温度变化不影响传感器输出的结论。 The measuring system, based on thermal compound sensor, can be used to measure gas-solid two-phase mass flow. During practical application, the thermal compound sensor shows inertia and delay. The model of the thermal compound sensor and simulating result are presented. From the simulating result, time constant and delay time are obtained. The result also shows that circumstance temperature change dose not affect the output of the thermal compound sensor.
出处 《传感技术学报》 CAS CSCD 2003年第2期144-146,共3页 Chinese Journal of Sensors and Actuators
基金 国家自然科学基金资助项目 (6 99740 19)
关键词 热式复合传感器 闭环结构 稳定性 响应速度 时间常数 滞后系数 thermal compound sensor close loop stability,response speed
  • 相关文献

参考文献5

二级参考文献8

共引文献16

同被引文献26

  • 1杨辉华,简捷,黄南民,樊鑫瑞.热式质量流量计特性曲线及其拟合方法的研究[J].化工自动化及仪表,1996,23(6):37-41. 被引量:18
  • 2Dell'Isola M, Cannizzo M, Diritti M. Measurement of high-pressure natural gas flow using ultrasonic flowmeters [J]. Measurement, 1997, 20(2): 75-89.
  • 3Vyas J C, Katti V R, Gupta S K, et al. A non-invasive ultrasonic gas sensor for binary gas mixtures[J]. Sensors and Actuators B, 2006, 115: 28-32.
  • 4Laghrouche M, Adaneb A, Boussey J, et al. A miniature silicon hot wire sensor for automatic wind speed measurements[J]. Renewable energy, 2005, 30: 1881-1896.
  • 5Viswanathan M, Rajesh R, Kandaswamy A. Design and development of thermal mass flowmeters for high pressure application[J]. Flow measurement and instrument, 2002, 13: 95-102.
  • 6Dijkstra M, de Boer M J, Berenschot J W, et al. Miniaturized thermal flow sensor with planar-integrated sensor structures on semicircular surface channels[J]. Sensors and Actuators A, 2008, 143: 1-6.
  • 7Chiu N F, Hsiao T C, Lin C W. Low power consumption design of micro-machined thermal sensor for portable spirometer[J]. Tamkang Journal of Science and Engineering, 2005, 8(3): 225-230.
  • 8Steurer J, Kohl F. Adaptive controlled thermal sensor for measuring gas flow[J]. Sensors and Actuators A, 1998, 65: 116-122.
  • 9Balla S J, Ashforth-Frosta S, Jambunathana K, et al. Appraisal of a hot-wire temperature compensation technique for velocity measurements in non-isothermal flows EJ]. International Journal of Heat and Mass Transfer, 1999, 42:3097-3102.
  • 10Berlicki T M, Murawski E, Osadnik S J, et al. Analysis of an ambient temperature influence on thermal thin-film microsensor[J]. Sensors and Actuators A, 1994, 45: 169-172.

引证文献2

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部