卧式高压加热器的虹吸破坏现象不仅与高加本身故障有关,它的发生、发展与表象还与其他相关设备系统有关,尤其当控制系统与被控设备之间热力、电气等相互作用的机理变得越来越复杂时。本文拟对高加的虹吸破坏现象作个简要分析,供大家参考。
The broken siphon of Horizontal high pressure heater is not only the heater's problem itself,if's happening,developing,and phenomena also connected with the other related devices,especially the themol or electric mechanisms between the control system and the controlled devices become more complex.This article analyzes the broken siphon of Horizontal high pressure heater for an example.