摘要
分析了 N1 0 0 - 90 /5 3 5型汽轮机危急遮断系统设计存在的问题 ,提出了采用 AST的具体有效的改造方案 ,通过技术改造 ,使该问题得以解决。
The occurring on the emergeney shut-down system of N100-90/55 steam turbine machine,the modification method are analysed.By taking advantage of AST,effectively methods was proposed.By technical innovations,all of the problems were solved.
出处
《山西电力》
2003年第3期52-53,69,共3页
Shanxi Electric Power