摘要
本文针对高压沿面放电活化气体的烟气脱硫技术,在静态实验研究的基础上进行了实验室冷态动态的实验研究。设计了便于反应和测量的动态实验装置。实验解释了电子束法脱硫技术中导致氨气泄漏的部分原因,验证了高压沿面放电脱硫技术可以在较低的运行电压下,达到提高脱硫效率,减少氨气泄漏的作用。
In this paper, in order to investigating the feasibility of high voltage plane discharge process for desulfurization, dynamical experiment in the lab was undertaken in normal temperature based on the former static quantitative experiments. From the experimental results, explanations are given for the cause of ammonia leak in the industrial process of removal SO2- Furthermore, the technology of high voltage plane discharge process, which works at a relatively low voltage, is proved to improve the efficiency of removal of SO2 and to reduce the ammonia leak.
出处
《工程热物理学报》
EI
CAS
CSCD
北大核心
2003年第4期711-713,共3页
Journal of Engineering Thermophysics
基金
北京市自然科学基金(No.3002006)
关键词
烟气脱硫
高压沿面放电
动态实验
flue gas desulphurization
high voltage plane discharge
dynamic experiment