摘要
在火力发电厂中,主蒸汽温度不但是保证机组热效率的重要指标之一,也是保证机组安全稳定运行的必要条件。分析了某电厂HG-220/9.81-1型锅炉主蒸汽温度低于设计值的原因和提出的改造方案及改造后的效果。通过对影响主蒸汽温度偏低的各种因素进行综合分析和论证,对喷燃器进行技术改造,使主蒸汽温度平均提高了17.8℃,保证了机组的安全经济运行。
In a thermal power plant, primary steam temperature is not only one of the parameters to ensure the thermal efficiency of the power generating set, but also the necessary condition for safe and stable opreation of the power generating set. the causes for the primary steam temperature of HG -220/9. 81-1 boiler, the upgrading scheme, and the effect of upgrading below its design value are analysed together with various factors having effect on the primary steam temperature, the upgrading of the spray burner increased the primary steam temperature by an average of 17.8C to ensure the safe and economic operation of the power generating set.
出处
《黑龙江电力》
CAS
2003年第3期209-213,共5页
Heilongjiang Electric Power
关键词
锅炉
主蒸汽温度
喷燃器调整标高
效果分析
boiler
primary steam temperature
spray burner
elevation
analysis of results