影响埋藏式心脏起搏器寿命的“先天”因素
被引量:1
摘要
影响心脏起搏器 (PM)寿命的相关因素有“先天”因素和“后天因素 ,但主要是前者。前者包括 :①电池因素 :电池容量和电池能量消耗 ;②电极因素 :电极阻抗、电极形状、激素释放电极、多孔电极、分形镀复电极、电极的位置 ;③导线 :导线的机械特性、构成导线的材料、导线的极性、导线的数量 ;此外还有PM的一些特殊功能 :自动夺获、重叠双相刺激、闭环刺激频率适应、睡眠功能。
出处
《中国心脏起搏与心电生理杂志》
2003年第3期224-226,共3页
Chinese Journal of Cardiac Pacing and Electrophysiology
参考文献17
-
1Oham OJ,Danilovic D. Improvements in pacemaker energy consumption and functional capability : four decades of progress [ J ]. PACE ,1997,20:2.
-
2Kindermann M, Schwaab B, Berg M, et al. Longevity of dual chamber pacemaker: device and patient related determiants [ J ]. PACE, 2001,24(5) :810.
-
3Glikson M, Hayes DL. Cardiac pacing: A review [ J]. Medical-Clin-North-Am,2001 ,85(2) :369.
-
4Parsonnet V. Berstein ADPerry GY The nuclear pacemaker:is renewed interest warranted [ J] ? Am J Cardioal, 1990,66(10) :837.
-
5Markewitz A, Kronski D, Kammeyer A, et al. Determinants of dual chamber pulse generators longevity [ J ]. PACE, 1995,18 ( 12 Pt 1 ) :2116.
-
6Schuchert A, Meinertz T. A randomized study on the effects of pacemaker programming to a lower output on projected pulse generation longevity[ J]. PACE ,2001,24(8 pt 1 ):1 234.
-
7Schwaab B, Schwerdt H, Heisel A, et al. Chronic ventricular pacing using an output amplitude of 1.0 volt[ J]. PACE , 1997, 20(9 pt 1 ) :2171.
-
8Coates S,Thwaites B. The strenth-duration curve and its importance in pacing efficiency: a study of 325 pacing leads in 229 patients [ J].PACE ,2000, 23(8) :1 273.
-
9Furman S, Garvey J, Hurzeler P. Pluse duration variation and electrode size as a factor in pacemaker longevity[ J]. J Throac Cardiovasc Surg,1975,69(3) :382.
-
10Grossly GH, Brinker JA, Reynolds D, et al. Steroid elution improves the stimulation threshold in an active-fixation atrial-fixation atrial permanent pacing lead. A randomized, controlled study. Model 4068 investigators[ J]. Circulation, 1995, 92(10) :2 935.
同被引文献10
-
1胡雪松,方卫华,衣卫民,刘幼文.经静脉植入心律转复除颤器并四年随访(摘要)[J].中华心律失常学杂志,1998,2(2):98-98. 被引量:1
-
2MOSS A J, HALL W J, CANNOM D S, et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Inverstigators (MAD1T) [ J ]. N Engl J Med, 1996, 335(26) : 1933 - 1940.
-
3Anonymous. A Comparison of antiarrhythmic - drug therapy with implantable defibrillators in patients resuscitated from near- fatal ventricular arrhythmias. The Antiarrhythmics versus Implanted Defibrillator(AVID) Investigators [ J ]. N Engl J Med, 1997, 337 (22) : 1576 - 1583.
-
4DORWARTH U, FREY B, DUGAS M, et al. Transvenous defibrillation leads : high incidence of failure during long - term folloe - up[ I]. J Cardiovasc Electrophysiol, 2003, 14( 1 ) : 38 -43.
-
5WASHIZUKA T, CHINUSHI M, TAGAWA M, et al. Inappropriate discharges by fourth generation implantable cardioverter defibrillators in patients with ventricular arrhythmias [ J ]. Jpn Circ J, 2001, 65(7) : 927 -930.
-
6DURU F, BAUERFELD U, CANDINAS R. Avoiding inappropriate ventricular tachyeardia detection due to T - wave oversensing in an implantable cardioverter defibrillator: a novel application of the electrograrn width criterion[J]. Europace, 2001, 3(1 ) : 80 -84.
-
7GOLLOB M H, SEGER J j. Current status of the implantable cardioverter - defibrillator[ J]. Chest, 2001, 119(4) : 1210 - 1221.
-
8MANOLIS A G, KATSIVAS A G, VASSILOPOULOS C V, et al. Implantable cardioverter defibrillator - an unusual case of inappropriate discharge during showering[ J]. J Interv Card Electrophysiol, 2000, 4(1): 265 -268.
-
9GLOTZER T V, GORDON M, SPARTA M, et al. Electromannetic interference from a muscle stimulation device causing discharge of an implantable cardioverter defibrillator : epicardial bipolar and endocardial bipolar sensing circuits are compared[ J]. Pacing Clin Electrophysiol, 1999, 21 (10) : 692 -693.
-
10王方正,华伟,张澍,陈新.69例植入型心律转复除颤器治疗患者的随访[J].中华心律失常学杂志,2001,5(2):120-122. 被引量:34
-
1李先,薛嘉.高龄患者安置埋藏式心脏起搏器的临床分析及防治并发症体会[J].四川医学,2001,22(9):820-820. 被引量:1
-
2李跃彬.学而不知老之将至[J].心理与健康,2005(12):28-28.
-
3孟素荣,彭健,宋跃明,许顶立,林春梅.双腔起搏器睡眠功能的设置及初步临床观察[J].中华心血管病杂志,2000,28(1):48-49. 被引量:4
-
4张萍,崔长琮,张全发,薛小临,吴军.两种低能量起搏电极的动态观察[J].中国心脏起搏与心电生理杂志,2001,15(1):34-36. 被引量:7
-
5孙洁,赵丽茹.人为什么会长寿[J].家庭医学(上半月),2004,19(21):51-51.
-
6陆基宗.谨防药物性衰老[J].科学养生,2017,0(3):53-54.
-
7爱华,柴(摘).喂养“聪明宝贝”七部曲[J].健康文摘,2006(9):10-10.
-
8薛梅,汤萍,邢浩莉,崔新凤.安置埋藏式心脏起搏器预防感染的措施[J].安徽卫生职业技术学院学报,2006,5(4):60-61.
-
9张文.睡眠功能新知[J].中国保健营养,2000(12):23-23.
-
10佰润系列之 延衰驻颜之本[J].家庭医药(就医选药),2006(8):55-55.