Discussion on National Standard GB 6167"Methods for Testing the Performance of Airborne Particle Counter

Discussion on National Standard GB 6167"Methods for Testing the Performance of Airborne Particle Counter
下载PDF
导出
摘要 Airborne pa rt icle counters are used widely to test the air cleanliness of cleanrooms. The cur rent Chinese national standard of airborne particle counter calibration, GB6167 -85, Methods for Testing the Performance of Dust Particle Counter, has kept the same for more than 10 years. It is necessary to be amended in time. This paper discusses the differences between Chinese airborne particle counter calibration procedure and other new calibration procedures in other countries, and points ou t the defects of current Chinese national standard.The draft of revised Chinese National Standard is also introduced. The new revised standard, Methods for Test ing the Performance of Airborne Particle Counter, covers two level calibrations: primary and secondary. Primary calibration procedure includes testing 6 kinds of performances:sample airflow rate, false counting, particle size accuracy and re solution, particle counting stability, counting efficiency and particle concentr ation limit. Secondary calibration is a relative comparing test method to verify the counting accuracy of calibrated airborne particle counters.Finally, how to keep the calibration traceability is suggested. Airborne pa rt icle counters are used widely to test the air cleanliness of cleanrooms. The cur rent Chinese national standard of airborne particle counter calibration, GB6167 -85, Methods for Testing the Performance of Dust Particle Counter, has kept the same for more than 10 years. It is necessary to be amended in time. This paper discusses the differences between Chinese airborne particle counter calibration procedure and other new calibration procedures in other countries, and points ou t the defects of current Chinese national standard.The draft of revised Chinese National Standard is also introduced. The new revised standard, Methods for Test ing the Performance of Airborne Particle Counter, covers two level calibrations: primary and secondary. Primary calibration procedure includes testing 6 kinds of performances:sample airflow rate, false counting, particle size accuracy and re solution, particle counting stability, counting efficiency and particle concentr ation limit. Secondary calibration is a relative comparing test method to verify the counting accuracy of calibrated airborne particle counters.Finally, how to keep the calibration traceability is suggested.
出处 《Transactions of Tianjin University》 EI CAS 2003年第2期153-156,共4页 天津大学学报(英文版)
关键词 AEROSOL airborne particle counter (AP C) particle calibration procedure national standard 航空粉尘计数器 性能测试 国家标准 GB6167 空气洁净度
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部