摘要 医用降温服的研制与应用对于解决医护人员的防暑降温具有重要意义。介绍了潜热蓄热型医用降温服的降温原理 ,测试了蓄热相变材料的热性能 ,初步评估了降温服的使用效果。结果表明 :潜热蓄热型医用降温服所用相变材料相变温度在 2 5℃左右为宜 ;TH 2 7复合相变材料相变温度合适、潜热蓄热密度高、性能稳定、原料充足且价格低廉 ,适合用作医用降温服的潜热蓄热材料 ;医用降温服采用铠甲式设计 ,上置若干口袋 ,可根据热舒适要求灵活置放降温袋 ,使用简便 ,具有良好的降温效果和热舒适感觉。 Special vest for medical garment with function of absorbing the body-released heatcan be of great importance to prevent heatstroke. Studies the design principle of this kind of vest and its thermal performance. Evaluates experimentally the thermal comfort sense of person wearing such vests . The results show that the melting temperature of phase change material (PCM) used in the vests should be around 25 ℃, that TH-27 PCM is of suitable melting temperature, large heat of fusion, stability, sufficient raw material and cheap costs, and that the vest style with small bags containing PCM is convenient to use and is effective in keeping relatively good thermal comfort sense.
机构地区 清华大学
出处 《暖通空调》 北大核心 2003年第U06期58-61,共4页 Heating Ventilating & Air Conditioning
关键词 医用降温服 热舒适 蓄热相变材料 空气流通 热环境 heat sinking vest, phase change material, thermal comfort
  • 相关文献

参考文献4

  • 1赵荣义.关于“热舒适”的讨论[J].暖通空调,2000,30(3):25-26. 被引量:103
  • 2宋潍晋.一护士长在非典病房晕倒[N].京华时报,2003年5月6日(第6版).
  • 3张寅平 胡汉平 孔祥冬 等.相变蓄能[M].合肥:中国科学技术大学出版社,1996..
  • 4Zhang Yinping, Jiang Yi. A simple method, T-history method,of determining the heat of fusion, specific heat and thermal conductivity of PCM, Measurement Science Technology, 1999,10(3) ;201 - 205.

二级参考文献1

共引文献102

同被引文献338

引证文献39

二级引证文献223

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部