期刊文献+

镍钛手用锉与不锈钢手用锉对弯曲根管成形能力的对比研究 被引量:6

Shaping ability of nickel-titanium and stainless steel hand-files in simulated curved root canals
下载PDF
导出
摘要 目的 :对比镍钛手用锉 (NiTiFLEX)与不锈钢K型锉 ,K Flex锉预备塑料块中的弯曲管的成形能力。方法 :3 6个内含相似弯曲根管的塑料块分为 3组 :( 1)镍钛手用锉组 ;( 2 )不锈钢K Flex锉组 ;( 3 )不锈钢K型锉组。均以逐步后退法预备根管 ,叠加根管预备前后的扫描图像 ,分析根管弯曲部分的形态变化。结果 :( 1)组基本维持原根管曲线 ,根尖 1/3平均角度偏移为 ( 1.2 8°± 0 .73°) ,( 2 )组、( 3 )组根管直化较明显 ,根尖 1/3平均角度偏移分别为 ( 10 .76°± 1.17°)和 ( 12 .5 8°± 1.0 9°) ,与 ( 1)组比较差异有显著性 (P <0 .0 1) ,( 2 )组与 ( 3 )组比较差异亦有显著性 (P <0 .0 1)。根管轴心偏移在弯曲部分向内 ,在根尖区向外 ,偏移量 ( 1)组最小 ,( 2 )组次之 ,( 3 )组最大 ,( 1)组与另两组间差异有显著性 (P <0 .0 1) ;除根尖处外 ,( 2 )组较 ( 3 )组的偏移量差异亦存在显著性 (P <0 .0 1)。 ( 2 )组、( 3 )组预备后的根管较 ( 1)组显著增宽 ,两组间只在距根尖 4mm差异有显著性 (P <0 .0 5 ) ,且均有根尖拉开和肘部形成。 ( 1)组无根尖拉开及肘部形成。结论 :镍钛手用锉较不锈钢手用锉能保持原根管曲线 。 Objective:To compare the shaping ability of nickel titanium hand files with that of stainless steel K Flexofiles and K files in simulated curved canals.Methods:A total of 36 canals were prepared by using either NiTiFlex files,K Flexofiles or K files in a stepback technique.Preinstrumental and postinstrumental images were taken,and assessment of the canal shapes was completed with a computer image analysis program.Results:Less transportation occurred with NiTiFlex files compared to K Flexofiles or K files( P< 0.01),and Average angle deviations of canal apical prepared with NiTiFlex files,K Flexofiles and K files were 1.28°±0.73,10.76°±1.17 and 12.58°±1.09,respectively.K Flexofiles and K files but NiTiFlex files created significantly greater width of canals,apical zips and elbows.Conclusion:NiTiFlex files produce more appropriate canal shapes than stainless steel hand files. [
作者 滕英
出处 《广东医学院学报》 2003年第3期239-241,共3页 Journal of Guangdong Medical College
关键词 镍钛手用锉 不锈钢手用锉 弯曲根管成形能力 对比研究 nickel titanium hand files stainless steel hand files curved root canal canal transportation
  • 相关文献

参考文献6

  • 1Kazemi RB,Stenman E ,Spangberg LS. Machining efficiency and wear resistance of nickel-titanium endodontic files[J]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod,1996,81(5):596-602.
  • 2Kazmi RB, Stenman E,Spangberg LS. A comparison of stainless steel and nickel-titanium H-type instruments of identical design:torsional and bending tests[J]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2000, 90(4):500-506.
  • 3Lam TV,Lewis DJ ,Atkins DR,et al. Changes in root canal morphology in simulated curved canals over-instrumented with a variety of stainless steel and nickel titanium files[J]. Aust Dent J,1999,44(1):12-19.
  • 4Bishop K, Dummer PM. A comparison of stainless steel Flexofiles and nickel-titanium NiTiFlex files during the shaping of simulated canals [J]. Int Endod J, 1997,30(1):25-34.
  • 5Pettiette MT,Metzger Z,Phillips C,et al. Endodontic complications of root canal therapy performed by dental students with stainless-steel K-files and nickel-titanium hand files[J]. J Endod, 1999,25(4):230-234.
  • 6Coleman CL,Svec TA. Analysis of Ni-Ti versus stainless steel instrumentation in resin simulated canals[J]. J Endod, 1999,23 (4) : 232-235.

同被引文献58

引证文献6

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;