12.5×10~4m^3储油罐底板阴极保护方案比选 被引量:8

THE COMPARISON AND SELECTION OF BOTTOM PLATE CATHODIC PROTECTION PLAN FOR 12. 5 ×10 (14)~m^3 STORAGE TANK
下载PDF
导出
摘要 对国内外储油罐底板内外侧各种阴极保护方法进行了分析对比。重点介绍了茂名分公司12.5×10~4m^3储油罐底板内外侧阴极保护方案:内侧为涂料加铝合金牺牲阳极阴极保护;外侧为涂料加混合金属氢化物网状阳极阴极保护。 Every kind of inside and outside cathodic protection method for bottom plate of storage tank at home and abroad was compared and analyzed. The inside and outside cathodeic protection plans of bottom plate for 12. 5×104 m3 oil storage tank in Mao Ming Branch Company was recommended emphatically. The inside method was coating and aluminum alloy sacrificial anode cathodic protection; the outside method was coating and mixed metal oxidate netted anodic cathodic protection.
作者 王晨 顾望平
出处 《石油化工设备技术》 CAS 2003年第3期45-49,共5页 Petrochemical Equipment Technology
关键词 储油罐底板 腐蚀 牺牲阳极 阴极保护 涂料 Storage oil tank bottom plate. Corrosion, Sacrificial anode, Cathodic protection, Coating
  • 相关文献

参考文献8

二级参考文献17

共引文献67

同被引文献37

  • 1杜富国,苏俊华.储罐外底板阴极保护系统的几个问题的探讨[J].石油化工腐蚀与防护,2006,23(1):41-43. 被引量:5
  • 2王爱萍,杜敏,陆长山,曹圣山,王庆璋.海洋平台复杂节点阴极保护电位分布的有限元法计算[J].中国海洋大学学报(自然科学版),2007,37(1):129-134. 被引量:9
  • 3API RP - 651 Athodic Protection of Aboveground Petroleum Storase Tanks[ S ]
  • 4SY0007-1999.钢质管道及储罐腐蚀控制工程设计规范[S].[S].,..
  • 5SY/T 0023-1997,埋地钢质管道阴极保护参数测试方法[S].
  • 6Rajani G l.Modem trend in impressesd current anodes for cathodic protection[A].Proc.6th Middle East Corrosion Conf[C].Bahrain:1994.383.
  • 7Reding J T.Performance of mixed metal oxide activated titanium anodes in deep ground beds[A].Corrosion 87[C].NACE,1987.9.
  • 8API RP 651-1991,Cathodic protection of aboveground petroleum storage tanks[S].
  • 9Mohammed Ali.Titanium ribbon anode grid type cathodic protection system for above ground storage tank bottoms with double containment-a case study[A].Corrosion 99[C].Paper No.289,NACE,1987.
  • 10API RP 651,Cathodic protection of aboveground petroleum storage tanks[S].1991.

引证文献8

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部