焦炭塔裙座长期受交变应力的作用极易产生裂纹 ,通过对裙座结构进行优化分析设计 ,采用应力较低的裙座结构 ,然后制定合理完善的焦炭塔裙座更换施工方案 ,对有裂纹的裙座成功地进行了更换 。
When the coke column skirt had been suffered from alternative stress for a long period of time,crack on it was easily occurring. Having made a rational and consummate replacement plan , the defects of the coke column skirt were successfully removed by way of replacing a new one which adopted optimum analyses and relatively low stress design on the structure.
出处
《压力容器》
2003年第7期25-28,共4页
Pressure Vessel Technology
关键词
焦炭塔裙座
裂纹
结构优化
应力分析
焊接
coke column skirt
crack
optimizing structure
stress analysis