摘要
探讨了电气消防设计中经常遇到的几个问题,包括消防风机、消防水泵等二次线路的设计,手动火灾报警按钮与消火栓按钮的功能区别及设置,火灾应急广播与火灾警报装置的设置等。
This paper probes into some problems often met in electrical and fi re design, including the design of secondary lines of fire fans and fire pumps, th e functional differences and arrangements of hand fire warning button and fire h ydrant button, the installation of fire urgent broadcasting and fire warning equ ipment, etc.
出处
《科技情报开发与经济》
2003年第7期261-262,共2页
Sci-Tech Information Development & Economy
关键词
电气消防设计
二次线路设计
火灾报警
消防联动控制
electrical and fire design
design of secondary line
fire warning
fire coordinated control