期刊文献+

炸药爆轰温度的瞬时多光谱测量 被引量:14

Measurement of the Denotation Temperature by Transient Multi-Wavelength Pyrometry
下载PDF
导出
摘要 从多光谱测温的基本原理出发 ,对瞬时多光谱爆温测量装置的工作原理、系统结构、爆温计算以及测量过程中可能引入的误差和进一步提高测量精度的方法进行了阐述和分析 利用该装置对液体炸药硝基甲烷的爆温进行了实际测量 ,取得了满意的测量结果 ,其爆温为 36 72K ,扩展不确定度为 10 0K(k =2 ) ,该温度下的光谱发射率为 0 .6 Based on multiwavelength Pyrometry, a detonation temperature measuring system is presented. The spectrogram of detonation′s radiation and of the standard lamp can be acquired to computer by spectrometer and gated ICCD system, respectively. The detonation temperature as well as the spectral emissivity can be calculated by applied the regression analysis method to the spectral ratio of the spectrum. Experimental results of the detonation temperature, the spectral emissivity of the liquid explosive Nitromethane (N.M.) are given. The methods about how to reduce the measurement errors are also fully discussed in particular.
出处 《光子学报》 EI CAS CSCD 北大核心 2003年第7期868-871,共4页 Acta Photonica Sinica
关键词 多光谱测温 爆温 回归分析 炸药 硝基甲烷 Detonation temperature Multiwavelength pyrometry Regression analysis
  • 相关文献

参考文献5

二级参考文献11

共引文献23

同被引文献130

引证文献14

二级引证文献78

相关作者