摘要
研究了铀钼共存体系中低含量铀和钼的测定方法。体系中铀含量高而钼含量低时,可采用CL-TBP萃淋树脂先分离铀,然后以硫氰酸盐光度法测定钼;体系中钼含量高而铀含量低时,可在1mol/LHNO3介质中沉淀分离铀,再用萃淋树脂富集铀,用水淋洗后,再以溴代光度法测定铀。结果表明,铀、钼回收率均在95%~105%之间,方法的相对标准偏差小于5%。
Determination of low concentration uranium and molybdenum in uraniummolybdenum system has been studied. The high concentration uranium is separated with CLTBP in nitric acid medium and the low concentration Mo can be determinated by thiocyanate spectrophotometry. The high concentration Mo can be precipitated and separated in 1 mol/L HNO3 medium, and the low concentration U is concentrated with CLTBP and determined with 5BrPADAP sepectrophotometry. The results show that relative standard deviation (RSD) is less than 5%, recovery of U and Mo are between 95%~105%.
出处
《湿法冶金》
CAS
2003年第2期106-111,共6页
Hydrometallurgy of China