竖直U型管地热换热器的准三维传热模型 被引量:44

A Quasi Three-dimensional Heat Transfer Model for Vertical U-Tube Geothermal Heat Exchangers
下载PDF
导出
摘要 在地热换热器原有研究工作的基础上,进一步考虑流体工质在钻孔深度方向上的温度分布,分析竖直埋管地热换热器钻孔内的传热过程,导出了竖直埋管地热换热器效能的解析式。由此,可以抛弃以往简化模型当中的不合理假设,为地热换热器的设计和模拟提供了更加精确合理的理论基础和计算方法。 In pursuit of a more advanced study of ground source heat exchangers the temperature distribution of fluid working media along borehole depth direction was investigated. By analyzing the heat transfer process in the borehole of a vertical embedded tube geothermal heat exchanger derived was an analytical expression of the efficiency of the said exchanger. Thus, it is possible to abandon the irrational assumptions contained in former simplified models and provide a more accurate and rational theoretical basis as well as a calculation method for the design and simulation of geothermal heat exchangers.
出处 《热能动力工程》 CAS CSCD 北大核心 2003年第4期387-390,共4页 Journal of Engineering for Thermal Energy and Power
关键词 地源热泵 地热换热器 热阻 效能 竖直埋管 ground source heat pump, geothermal heat exchanger, thermal resistance, efficiency
  • 相关文献

参考文献8

  • 1曾和义,方肇洪.U型管地热换热器中介质轴向温度的数学模型[J].山东建筑工程学院学报,2002,17(1):7-11. 被引量:60
  • 2BOSE J E, PARKER J D, MCQUISTON F C. Design/data manual for closed-loop ground-coupled heat pump systems[R]. Atlanta: ASHRAE,1985.
  • 3YU M Z, DIAO N R, FANG Z H. A pilot project of the closed-loop ground-source heat pump system in China[A]. Proceeding of IEA 7^th Heat Pump Conference[C]. Beijing: 2002.37-41.
  • 4KAVARAGH S P.Ground-source heat pumps[J] .ASHRAE Journal,1998,40(10) :22 - 26.
  • 5ZENG H Y, DIAO N R, FANG Z H. A finite line-source model for borehohs in geothermal heat exchangers[J]. Heat Transfer - Asfan Research, 2002, 31(7) :558 - 567.
  • 6GU Y O, NEAL D L. Development of an equivalent diameter expression for vertical U- tubes used in ground- coupled heat pumps[J].ASHRAE Trans, 1998,104(2) :347 - 355.
  • 7DIAO N R, CUI P, FANG Z H. The thermal resistance in a borehole of geothermal heat exchanger[A]. Proc 12^th International Heat Transfer Conference[C]. France: 2002.239 - 343.
  • 8HELLSTROM G.Ground heat storage, Doctoral Thesis[D]. Sweden: University of Lund, 1991.

二级参考文献6

  • 1方肇洪 刁乃仁 苏登超 等.竖直U型埋管地源热泵空调系统的设计与安装[J].现代空调,2001,(10):101-105.
  • 2Bose J E,Parker J D,McQuiston F C. Design/data manual for closed-loop ground-coupled heat pump systems[M].Atlanta:ASHRAE,1985.
  • 3Kavaragh S P.Ground-source heat pumps[J].ASHARE Journal,1998,40(10).
  • 4Gu Y,O′Neal D L.Development of an equivalent diameter expression for vertical U-tubes used in ground-coupled heat pumps[J].ASHRAE Transactions,1998,104(2):347-355.
  • 5Diao N R,Cui P,Fang Z H.The thermal resistance in a borehole of geothermal heat exchangers[C].Proc.12th International Heat Transfer Conference,2002.
  • 6曾和义,刁乃仁,方肇洪.竖直埋管地热换热器的稳态温度场分析[J].山东建筑工程学院学报,2002,17(1):1-6. 被引量:23