摘要 由化学酸碱平衡理论及质子条件建立了pH值、磷酸盐浓度与R值算法的数学模型,通过LabView编程,计算分析了协调磷酸盐处理的测量误差对R值测量的影响,并根据计算结果优化出协调磷酸盐处理过程中pH值、磷酸盐控制的最佳范围,对我国广泛应用的协调磷酸盐处理有一定的指导作用. A mathematical model for the calculation of pH,phosphate concentration and R , on the basis of the chemistry balance of acidbase theory and proton condition equation, has been established. At the same time, using LabView programs, the effect of the measurement error in congruent phosphate treatment on the measurement of R is analyzed, and the proper controlling range of pH and phosphate during the congruent phosphate treatment is optimized, which has a guiding effect on the project of congruent phosphate treatment widely applied in our country.
出处 《天津大学学报(自然科学与工程技术版)》 EI CAS CSCD 北大核心 2003年第4期486-488,共3页 Journal of Tianjin University:Science and Technology
关键词 炉水 R值检测 误差分析 钠磷摩尔比 水质调节 汽包锅炉 化学酸碱平衡理论 磷酸盐 PH值 water in drum boiler sodium to phosphate ratio error analysis
  • 相关文献

参考文献6

  • 1肖作善.热力设备水汽化过程[M].北京:水利电力出版社,1987..
  • 2天津大学分析化学实验室.实用分析化学[M].天津:天津大学出版社,1995..
  • 3Sinclair K, Bartlett P. Operational problems encountered in the control of boiler feedwater quality [ J ]. Corrosion Prevention and Control, 1995,42(3):53--59.
  • 4Buecker Brad. Boiler water treatment: computer program helps control chemistry and prevent corrosion [ J ]. Corrosion Prevention and Control, 1995,42( 1 ) :5--7.
  • 5Hendrix David E. Hydrogen attack on waterwall tubes in a high pressure boiler [ J ]. Materials Performance, 1995,34(8) :46--51.
  • 6Sharma R P. Corrosion in boilers: its prevention & control[J]. Chemical Engineering World, 1996,32(2) : 73--77.

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部