摘要
采用连续式UV-Fenton氧化-生化工艺处理邻氯苯酚废水,通过UV-Fenton氧化预处理,可以去除大部分的邻氯苯酚,将大分子降解成低分子脂肪烃化合物,从而提高了废水的可生化性.对于CODcr1000mg/L左右,邻氯苯酚浓度为625mg/L的废水,H2O2为1/4Qth理论投加量时,经过UV-Fenton-生化组合处理工艺处理,CODcr去除率可达到64.4%,邻氯苯酚去除率可达94.6%.
An appartus for the UVFentonBiochemistry decomposition of orthochlorophenol wastewater was established. Wastewater was treated by ultraviolet light/hydrogen peroxide/fenton's reagent oxidation (UV/H2O2/Fe2+) method. Through the pretreatment of orthochlorophenol wastewater by UVFenton system, it will be easy to treat by using biochemistry methods. At the same time, most of orthochlorophenol will be degraded. When the original concentration of CODcr was 1 000 mg/L and orthochlorophenol was 625 mg/L, the wastwater reacted with H2O2 at 25 % CODcr,in(1/4Qth) and the ratio of Fe2+∶ H2O2 being 1∶20, through the treatment of UVFentonbiochemistry system, 64.4 % CODcr and 94.6 % of orthochlorophenol were moved.