期刊文献+

燃煤锅炉烟气氟化物检测方法的研究 被引量:1

Study on monitoring method for fluoride concentration in flue gas of coal combustion boiler
下载PDF
导出
摘要 由于燃煤锅炉烟气氟化物的低浓度特性,直接采用工业污染源烟气氟化物浓度检测标准方法测定燃煤锅炉烟气氟化物常导致测定结果产生较大的偏差。本文通过试验对造成测定结果偏差的原因进行了系统研究,对气态氟和尘态氟采样方法、采样装置、采样参数和氟化物测量方法等检测程序进行了合理改进,使之较好地适用于燃煤锅炉烟气中低浓度氟化物的准确测定。 Due to the characteristic of low concentration in flue-gas fluoride of coal combustion boiler, the bigger error is caused by directly using the standard monitoring method for the fluoride concentration in flue gas of industrial pollution resource to measure flue-gas fluoride of coal combustion boiler. Based on experiments, the systematic study on the cause for the error of measuring result is carried out, and the monitoring programmers of the sampling methods for gas-phase fluorine and dust-phase fluorine, the sampling equipments, the sampling parameters, the measuring methods for fluoride and so on are reasonably improved to better adapt to accurately measuring low-concentration fluoride in flue gas of coal combustion boiler.
出处 《辽宁工程技术大学学报(自然科学版)》 CAS 北大核心 2003年第4期517-519,共3页 Journal of Liaoning Technical University (Natural Science)
基金 国家重大基础研究发展规划项目(G1999022211) 辽宁省高等学校科学研究计划项目(202183384)
关键词 燃煤锅炉 烟气检测 氟化物 检测方法 气态氟 尘态氟 大气污染物 煤燃烧 coal combustion boiler gas-phase fluorine dust-phase fluorine monitoring method
  • 相关文献

参考文献3

  • 1国家环境保护局.空气和废气监测分析方法[M].北京:中国环境科学出版社,1995.368-374.
  • 2QI Qingjie, LIU Jianzhong, CAO Xinyu,et al. Experimental study on Behavior of Floutine and Retenting of Fluorine and Suphur During Coal Combustion in Small Boiler[A].Proceedings of 10^st ICCS [C].Taiyuan:Shanxi science and Technoloy Prees,1999.
  • 3Christopher F B, Anders W A. Emissions of Vapor-Phase Fluorine and Ammonia from Columbia Coal-Fired Power Plant[I].Environ.Sci.Teclmol, 1985, 19(5): 1099-1103.