摘要
介绍东糖实业集团公司热电厂新1号130t/h循环流化床锅炉(简称CFB锅炉)的基本结构和特点,对该锅炉在安装调试中出现的问题进行分析并采取相应的改进措施,使机组顺利投入运行。
The structure and features of the new 130 t/h circulating fluidized bed boiler (CFBB) No1 in Cogeneration Power Plant of Donta Group Co.,Ltd.are described.The analysis of the problems encountered in the boiler commissioning test and the treatment are presented as well.
出处
《广东电力》
2003年第3期81-84,共4页
Guangdong Electric Power