期刊文献+

广蓄电站6~#机推力瓦烧损诊断及处理 被引量:3

Diagnosis and Treatment of the Damage of GVVPESS Unit No.6 Thrast Bearing Pad
下载PDF
导出
摘要 广蓄电站二期工程6#机在调试中,因推力瓦本身缺陷(瓦的表面加工制造质量及瓦的结构、形状、设计欠合理),先后发生2次烧瓦事故.针对这一问题提出了改造措施,事故处理后,机组在各种工况下安全运行了2年多,推力瓦一直运行良好.这一成功的改造方案供设计、制造及安装部门解决大型类似机组推力瓦烧损问题参考. During the trial run of unit No. 6 of stage - 2 Guangzhou Water Pumping and Energy Storage Station (GWPESS), the own defects thrust bearing pads (defects in the pad's surface, structure and shape) caused damages twice. The problem has been solved by relevant special measures. As a result of the treatment, the unit and the thrust bearing have been in good operation for two years more. This successful transformation provided the design, manufacturing and installation departments valuable experience for treatment the bearing pad damages of similar large generating units.
作者 肖智
出处 《大电机技术》 北大核心 2003年第4期30-32,共3页 Large Electric Machine and Hydraulic Turbine
关键词 推力轴承 推力瓦 烧损 故障诊断 故障处理 水轮机 广蓄电站 hydrogenerator damage of thrust bearing pad diagnosis
  • 相关文献

同被引文献16

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部