期刊文献+

柳林电力有限责任公司2#炉制粉系统改造

The Improvement of No.2 Boiler's Pulverized-coal System of Liulin Power Ltd
下载PDF
导出
摘要 对柳林电厂 2 #锅炉制粉系统存在的主要问题 ,即粗、细粉分离器效率低 ,三次风带粉量大 ,排烟温度高 ,制粉系统爆炸等进行了分析和研究。实施改造后 ,制粉系统单耗下降了 4 .6 5kWh/t ,细粉分离器效率提高了 2 .1% ,三次风含粉浓度下降了 6 .8g/m3,制粉系统出力明显增大。同时 ,消除了煤粉滞流 。 Through the study and the analysis of the main problems existing in the present pulverized coal system of the Boiler No.2 of Liulin Electric Power Plant,that is the low efficiency of the coarse and the fine coal separators,the more amount of coal conveyed by the third air flow,higher exhausted flue gas temperature and burning out of the pulverized coal system,some modifications are adopted to the coarse and the fine coal separators, As a result,the unit energy consumption of the pulverized coal system is decreased by 4.65 kWh/t, the efficiency of the fine coal separetor is increased by 2.1 %, the coal density of the third air flow is decreased by 6.8 g/m 3 and the output ability of the system is increased obviously. At the meantime, the stagnation pnenomenon is eliminated and the anti explosion ability of the pulverized coal system is improved.
出处 《电力学报》 2003年第1期81-82,共2页 Journal of Electric Power
关键词 锅炉 制粉系统 技术改造 细粉分离器 磨煤机 柳林电力有限责任公司 boiler pulverized coal system improvement
  • 相关文献

参考文献2

  • 1邢博雄.柳林电厂2#炉制粉系统改造前试验报告[R].,2000..
  • 2邢博雄.柳林电厂2#炉制粉系统改造后调整试验报告[R].,2000..

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部