期刊文献+

Snoreguard矫治器治疗阻塞性呼吸暂停综合征疗效分析

The study on the effect of Snoregurad appliance on OSAS
下载PDF
导出
摘要 目的 :探讨 Snoreguard矫治器对阻塞性呼吸暂停综合征 ( OSAS)患者气道、睡眠结构的影响。方法 :选择 2 6岁~ 5 9岁患有 OSAS的患者 8例 ,在睡眠时分别配戴 Snoreguard矫治器 ,同时结合应用头颅侧位片、夜间多导睡眠图监测来测定分析配戴 Snoreguard矫治器的测量指标 ,进行统计分析。结果 :配戴 Snoreguard矫治器后 ,8例患者的AI值、平均呼吸暂停时间、AHI值均有显著性的降低 ( P<0 .0 1) ,Sa O2 显著增加 ( P<0 .0 1) ,HI值降低显著 ( P<0 .0 5 )。鼾声指数大幅度减轻甚至消失 ( P<0 .0 1)。配戴矫治器后下颌在水平向和垂直向的位移平均为 2 .0 3 mm和 8.74m m,IAS无显著变化 ,MAS变化明显 ( P<0 .0 5 ) ,最显著性改变的是上气道后间隙 ( SPAS) ( P<0 .0 1) ,SPL 减少 3 .64m m。结论 :Snoreguard矫治器是通过将下颌限制在一个前伸位 。 Objective:The purpose of the present study was evaluate the effctiveness of Snoreguard appliance on OSAS by combining the use of overnight polysomnography and cephalometry.Methods:8 OSAS patients(male 6,female 2),aged from 26 to 59 years.Those patients wore the Snoreguard appliance when sleeping in night.The association between the improvement of respiratory variables and the cephalometric variables were investigated on the basis of linear correlation anasis.Results:There was significant decreased in the average.The Average Apnea Index,Respiratory Disturbance Index( P <0.01),the lowest SaO 2 value increased( P <0.01),horizontal and vertical mean changes in mandibular postion while the appliance was worn were 2.03 mm and 8.75 mm.The most significant increased( P <0.01) was the superior airway space,while the mean middle airway space increased.The inferior airway space didn′t change significantly.SPL was decreased by 3.64 mm.Conclusion:The reduction in the rate of airway obsructive events is attributed to the effect of appliance on the orophargneal structures.
出处 《临床医药实践》 2003年第7期490-492,共3页 Proceeding of Clinical Medicine
关键词 Snoreguard矫治器 治疗 阻塞性呼吸暂停综合征 疗效分析 obstructive sleep apnea syndrome snoreguard appliance PSG
  • 相关文献

参考文献5

  • 1刘月华.阻塞型睡眠呼吸暂停综合征的临床表现、病因机制及其诊断[J].中华口腔正畸学杂志,1994,10(2):90-92. 被引量:12
  • 2Rivlin J,Hoffstein V. Upper airway morphology in patients with idiopathic obstructive sleep apnea[J]. Am Respir Dis, 1984,129 : 355.
  • 3Schmidt-Nowarat W,Lowe AA,Wiegand Let al. Oral appliances for the treatment of snoring and obstructive sleep apnea :A review[J]. Sleep, 1995,18 : 722.
  • 4Menn SJ,Loube DI. The mandibular repositioning device:Role in the treatment of obstructive sleep apnea [J].Sleep,1996,19:794.
  • 5Bonham PE,Currer GF,Orr WC et al. The effect of a modified functional appliance on obstructive sleep apnea[J]. Am J Orthod Dentofac Orthop, 1998,94 : 384.

共引文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部