摘要
根据硅光电池特性、辐射测温原理 ,分析了硅光电池探测灵敏度和测量距离、测量通路介质、辐射率等对全辐射温度计、单色温度计、比色温度计测温精度的影响。
According to the characters of Si-light cell and theories of light radiation temperature measurement,it analyzes that elements such as sensitivity of temperature measurement of Si-light cell and measurement distance,measurement media path,radiation ratio,affects measurement precision of the full radiation thermometor,single color thermometor and color contrast thermometor.
出处
《焊管》
2003年第4期21-24,61,共4页
Welded Pipe and Tube
关键词
辐射测温
距离系数
介质吸收
辐射率
比色测温
硅光电池
误差分析
温度计
radiation measurement temperature distance factor media absorbing radiation ratio color contrast measurement temperature