期刊文献+

应用Cole-Cole公式分析蛙血液细胞介电谱 被引量:26

THE DIELECTRIC SPECTRA OF FROG BLOOD CELL ANALYSIS BY COLE-COLE FORMULA
下载PDF
导出
摘要 利用Cole Cole公式对 10 4~ 10 8Hz频率段的蛙血液细胞介电谱进行了曲线拟合分析 ,建立了蛙血液细胞Cole Cole参数 :高频段相对介电常数εh=6 0 ,第一相对介电增量Δε1=4 90 0 ,第二相对介电增量Δε2 =12 0 0 ,第一特征频率 f1=0 .2MHz,第二特征频率 f2 =2 .4MHz,第一相位角 β1=0 .92 ,第二相位角 β2 =0 .93,低频段电导率k1=3.38ms/cm。 We have analyzed the dielectric spectra of frog blood cell by Cole-Cole formula at frequency range of 104Hz∼108Hz. By using curve fitting, we established the Cole-Cole parameters of the frog whole blood cell: Relative permittivity at high frequency Εh = 60, The first relative permittivity increment ΔΕ1 = 4900, The second relative permittivity increment ΔΕ2 = 1200, The first characteristic frequency f1 = 0.2 MHz, The second characteristic frequency f2 = 2.4 MHz, The first phase angle β2 = 0.92, the second phase angle β2 = 0.93, Conductivity at low frequency f2 = 3.38 ms/cm.
出处 《中国生物医学工程学报》 EI CAS CSCD 北大核心 2003年第4期309-312,共4页 Chinese Journal of Biomedical Engineering
基金 日本国文部省奖学金 日本国际教育交流协会奖学金资助项目
关键词 血液细胞 介电谱 相对介电常数 电导率 介电损耗因子 损耗角正切 Cole-Cole公式 蛙血 Biochemistry Cells Dielectric liquids Permittivity
  • 相关文献

参考文献15

  • 1鲁勇军,余珏.细胞和组织射频介电弛豫特性分析[J].基础医学与临床,1995,15(3):44-48. 被引量:5
  • 2赵孔双.微小生物细胞的介电研究方法[J].生物物理学报,2000,16(1):172-182. 被引量:19
  • 3马青,汤治元,赵伟红,焦效兰,张咸宁.蛙血细胞被动电生理特性的数据分析[J].中国医学物理学杂志,2001,18(4):231-233. 被引量:12
  • 4鲁勇军,余珏,任燕华,张玉荣,张建新.急性心梗病人血红细胞悬液射频介电弛豫特性的初步研究[J].北京生物医学工程,1995,14(1):36-39. 被引量:4
  • 5雷建平,裘乐乐,赵孔双.分散系介电理论的数值计算方法[J].计算机与应用化学,2001,18(3):233-236. 被引量:1
  • 6Basoli A, Bordi F, Cametti C, et al. Structural alteration of erythrocyte cell membrane in presence of artificial prostheses: a radiowave dielectric spectroscopy study[J]. J Biomed Mater Res,2002,59(1):100-109.
  • 7Bonincontro A, Gimsa J, Risuleo G, et al. Critical analysis of the impedance method for the evaluation of permittivity and conductivity of the plasma membrane[J]. Membr Cell Biol, 2000,14(1):129-135.
  • 8Lu Y, Yu J, Ren Y. Dilectric properties of human red blood cells in suspension at radio frequencies[J]. Bioelectromagnetics,1994,15(6) :589-591.
  • 9Bordi F, Cametti C, Misasi R, et al. Conductometric properties of human erythrocyte membranes: dependence on haematocrit and alkali metal ions of the suspending medium[J ]. Eur Biophys J, 1997,26:215-225.
  • 10Beving H, Eriksson LE, Davey CL, Kell DB. Dielectric properties of human blood and erythrocytes at radio frequencies (0.2-10 MHz) ; dependence on cell volume fraction and medium composition[J]. Eur Biophys J, 1994,23(3) :207-215.

二级参考文献9