期刊文献+

石化废水回用于循环冷却水的中试试验研究 被引量:5

Pilot Plant Research On Reuse of Petro-Chemical Wastewater for Circulating Cooling Water System
下载PDF
导出
摘要 以大庆某化工厂石化废水二级处理出水作为回用于工业循环冷却水水源 ,通过对废水回用前后的水质分析和相关处理技术的调查 ,确定采用曝气生物滤池和臭氧生物活性炭处理工艺进行中试研究。试验结果表明 :经本工艺处理后 。 The effluent of a secondary wastewater treatment plant treating petro chemical wastewater in Daqing Oil Field was appointed to reuse for the make up to circulating cooling water system. The data of water quality before and after reuse were studied, and technical investigation was done. A pilot plant with processes of aerobic bio filter (BAF), ozonization and biological activated carbon (BAC) treatment was conducted. The experimental results show that these processes are enough to produce water suitable to use for circulating cooling water system.
出处 《给水排水》 CSCD 北大核心 2003年第7期43-46,共4页 Water & Wastewater Engineering
  • 相关文献

参考文献4

二级参考文献5

  • 1[苏]谢甫钦柯,[苏]刘荣诺夫 著,刘存礼.臭氧化法水处理工艺学[M]清华大学出版社,1987.
  • 2EdwardJ.Bouwer,etal.BiologicalProcessesinDrinkingWaterTreatment[].Journal of the American Water Works Association.1988
  • 3Thoma C. Voice,et al.Biological Activated Carbon in Fluidized FBedReactors for the Treatment of Groundwater Contaminated with Volatile Aromatic Hydrocarbons[].Water Research.1992
  • 4Takeuchi,Yasushi,et al.Removal of organic substances from water by ozone treatment followed by biological activated carbon treatment[].Water Science and Technology.1997
  • 5Kim,Woo Hang,et al.Pilot plant study on ozonation and biological activated carbon process for drinking water treatment[].Water Science and Technology.1997

共引文献41

同被引文献55

引证文献5

二级引证文献13