摘要 目的 评价彩色多普勒超声 (Dus)和胎心监护(NST)对产前诊断胎儿脐带绕颈的临床意义 ,以期提高诊断符合率。 方法 对826例晚期妊娠孕妇产前1~10d行Dus和NST检查预测胎儿脐带绕颈 ,按不同检查方法分为Dus组、NST组和联合组。记录3组脐带绕颈的预测数和实际发生数 ,计算各自的诊断符合率、阴性预测值、敏感性、特异性和准确率。 结果 Dus组患者和NST组患者的诊断符合率分别为86.5 %和87.2% ;联合组94.0 % ,较前2组明显提高 (χ2=17.38,P<0.01) ,且敏感性、特异性和准确率均有提高 (χ2=7.77、20.85和9.97 ,均P<0.01)。 结论 Dus和NST对产前诊断胎儿脐带绕颈具有相近的临床意义 ,NST联合Dus检查能大大提高胎儿脐带绕颈的诊断符合率。 Objective To investigate the clinical value of color Doppler ultrasonography(Dus)and non-stress test(NST)in prenatal diagnosis of umbilical cord around neck.Methods Eight hundred twenty six pregnant women were studied within1~10days before delivery by Dus and/or NSTto predict umbilical cord around neck,they were divided into Dus group,NSTgroup and the combined group according to different methˉods.The predictive numbers and actual numbers were recorded and the rate of diagnostic coincidence,negative predictive value,sensitivity,specificity and accuracy were calculated.Results The rate of diagnostic coincidence was86.5%in Dus group and87.2%in NSTgroup,while it was94.0%in the combined group(χ 2 =17.38,P<0.01).The sensitivity,specificity and accuracy rate were also improved in the combined group(χ 2 =7.77,20.85and9.97,P<0.01).Conclusion NST has the same clinical value as Dus in prenatal diagnosis of umbilical cord around neck and combined application of Dus and NSTcould remarkably increase the rate of diˉagnostic coincidence.
出处 《浙江医学》 CAS 2003年第7期412-414,共3页 Zhejiang Medical Journal
关键词 DUS NST 产前诊断 胎儿脐带绕颈 临床意义 Color Doppler ultrasonography Non-stress test Umbilical cord around neck
  • 相关文献

参考文献6

二级参考文献10

  • 1李玉萍,梁月华.945例脐带异常对围产儿的影响[J].中国实用妇科与产科杂志,1994,10(5):291-292. 被引量:21
  • 2刘俊英.脐带绕颈的诊断与处理[J].实用妇科与产科杂志,1992,5(8):229-229.
  • 3乐杰.高危妊娠.妇产科学(第4版)[M].北京:人民卫生出版社,1998.148-150.
  • 4何秀琼.胎心率电子监护变化型减速的临床意义[J].中华妇产科杂志,1986,21:133-133.
  • 5[4]Schulman H, et al. Fregnancy surveillance with Doppler velocimetry of uterine and umbililical artery. Am J Obstet Gvnecol 1989,160: 192-196
  • 6[5]Hendricks SK, et al, Dopply umbilical artery waveform indicesnoal values from fourteen to fortytwo weeks.Am J Obstet Gyneco1989,161:761-765
  • 7[6]Trudinger Bj, et al. A comparison of fetal heart rate monitoring and umbilical artery wareforms in the reconition of fetal compromise. Br Obstet Gynecol 1986,93:171-175
  • 8王淑贞.高危妊娠的重点监护.妇产科学(第3版)[M].北京:人民卫生出版社,1992.521-526.
  • 9邝健全,妇产科学(第4版),1998年,148页
  • 10连旭明,徐蕴华.脐带绕颈的产前超声诊断:附518例分析[J].中华妇产科杂志,1991,26(3):171-172. 被引量:36

共引文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部