期刊文献+

电梯复合曳引钢带无损检测方法的研究 被引量:8

Study on non-destructive method of combined traction steel band for lift
下载PDF
导出
摘要 基于电梯复合曳引钢带强度损失的原因,对钢带现有无损检测方法进行比较和分析,通过对钢带电阻检测法的试验验证,得出了钢带剩余强度减少率与钢丝绳芯电阻变化率之间的关系,在此基础上提出了钢带无损检测的合理化建议。 Based on reasons for intensity loss of the combined traction steel band for the lift , the paper compares and analyzes the current non-destructive testing methods.Through the test verification of the steel band resistance detecting method , the relationship between the decrement rate of the residual intensity of the steel band and resistance change rate of the steel rope core is gained .Based on this , the paper puts forward proper suggestions for non-destructive testing of the steel band.
出处 《起重运输机械》 2015年第8期103-105,共3页 Hoisting and Conveying Machinery
基金 国家质检公益项目(2012104016-7)
关键词 电梯 钢带 剩余强度 无损检测 lift steel band residual intensity non-destructive testing