期刊文献+

大体积钢筋混凝土裂缝控制——水产研究所综合楼地下室大体积混凝土裂缝控制措施 被引量:1

Measures to control the crack in mass steel concrete--measures to control the mass concrete crack in the synthetical building basement of Aquatic Produ cts Research Institute
下载PDF
导出
摘要 大体积混凝土的截面尺寸较大,在混凝土硬化期间,水泥水化过程中所释放的水化热产生的温度变化和混凝土收缩,以及外界约束条件的共同作用而产生的温度应力和收缩应力,容易导致大体积混凝土结构出现裂缝.在施工中,通过温度、收缩应力计算,倒推混凝土入模温度,改善原材料、施工作业条件等方法,合理控制温升,延缓降温速率,可有效控制有害裂缝. The section size of mass concrete is relatinely greater. During t he hardening of concrete and the watering of cement, temperature stress and cont ract stress which are caused by the temperature change, the concrete contracts a nd the outer limited conditions can easily lead to the concrete crack in mass co ncrete. In the construction, the harmful crack can be effectively controlled by calculating the temperature and contract stress, counter-deducing the income p attern temperature and improving raw material and building conditions.
作者 李波 马卫民
出处 《宁夏工程技术》 CAS 2003年第3期277-279,共3页 Ningxia Engineering Technology
关键词 大体积钢筋混凝土 裂缝控制 入模温度 收缩应力 计算 浇筑 水产研究所综合楼 地下室 mass concrete the income pattern temperature crack control
  • 相关文献

参考文献4

  • 1杨嗣信 等.高层建筑施工手册[M].北京:中国建筑工业出版社,1995..
  • 2国家建设部.GB 50204-2002混凝土结构工程施工质量及验收规范[S].北京:中国建筑工业出版社,2002..
  • 3徐帆.建筑施工手册[M].北京:中国建筑工业出版社,1997.458-465.
  • 4成荣先.大体积混凝土冬期施工[J].宁夏工程技术,2002,1(4):386-388. 被引量:1

二级参考文献3

  • 1黑龙江省寒地建筑科学研究院.JGJ 104-97建筑工程冬期施工规程[S].北京:中建筑工业出版社,1997.
  • 2赵志(氵晋),赵帆.高层建筑基础工程施工[M].北京:中国建筑工业出版社,1991.431-479.
  • 3国家建设部.GB 50204-92混凝土工程施工及验收规范[S].北京:中国建筑工业出版社,1992.