期刊文献+

EFFECTS OF LOW-FREQUENCY ELECTROACUPUNCTURE ON THE IMMUNOLOGIC FUNCTION IN MORPHINE DEPENDENCE RATS 被引量:1

EFFECTS OF LOW-FREQUENCY ELECTROACUPUNCTURE ON THE IMMUNOLOGIC FUNCTION IN MORPHINE DEPENDENCE RATS
下载PDF
导出
摘要 Objective: To observe the effect of low-frequency electroacupuncture (EA) on the immunologic function in morphine dependence rats. Methods: Forty SD rats were used in this study. Morphine-dependence model was established by intraperitoneal injection of morphine hydrochloride continuously for 5 days and hastened by administration (i.p) of Naloxone. These rats were randomly divided into control, model, EA and auto-demorphinization groups with 10 cases being in each group. In EA group, "Guanyuan"(CV 4),"Mingmen"(GV 4), etc. were punctured and stimulated electrically. Positive T lymphocyte subgroups, CD + 4 and CD + 8 in the peripheral blood were detected with fluorescence immuno-assay. Results: In model group, serum percentage of CD + 4 and CD + 4/CD + 8 decreased considerably in comparison with those of control group (P<0.01); while in EA group, CD + 4 level and CD + 4/CD + 8 increased significantly compared with those of model group (P<0.01); and no significant differences were found between auto-demorphinization group and model group and between EA and control groups in these two indexes. Conclusion: Low-frequency EA can promote the restoration of the immune function of morphine dependence rats. Objective: To observe the effect of low-frequency electroacupuncture (EA) on the immunologic function in morphine dependence rats. Methods: Forty SD rats were used in this study. Morphine-dependence model was established by intraperitoneal injection of morphine hydrochloride continuously for 5 days and hastened by administration (i.p) of Naloxone. These rats were randomly divided into control, model, EA and auto-demorphinization groups with 10 cases being in each group. In EA group, 'Guanyuan'(CV 4),'Mingmen'(GV 4), etc. were punctured and stimulated electrically. Positive T lymphocyte subgroups, CD + 4 and CD + 8 in the peripheral blood were detected with fluorescence immuno-assay. Results: In model group, serum percentage of CD + 4 and CD + 4/CD + 8 decreased considerably in comparison with those of control group (P<0.01); while in EA group, CD + 4 level and CD + 4/CD + 8 increased significantly compared with those of model group (P<0.01); and no significant differences were found between auto-demorphinization group and model group and between EA and control groups in these two indexes. Conclusion: Low-frequency EA can promote the restoration of the immune function of morphine dependence rats.
出处 《World Journal of Acupuncture-Moxibustion》 2003年第2期33-35,共3页 世界针灸杂志(英文版)
基金 TheprojectwassupportedbyagrantfromtheHealthBureauofHubeiProvince(No[2 0 0 1 ]1 3 3 )
关键词 Low-frequency EA Morphine-dependence Immunologic function 低频电针 吗啡依赖 免疫功能 CD4抗原
  • 相关文献

同被引文献4

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部