三低技术联合生理盐水技术在头颈部CTA的应用价值 被引量:6

Value of Three-Low Technique Combined Saline in CTA of the Head and Neck
原文传递
导出
摘要 目的为降低患者辐射剂量、减少对比剂副作用,探讨三低技术(即低管电压、低剂量、低浓度)联合生理盐水技术在256层CT头颈部血管成像(CTA)中的应用价值。方法随机将120例头颈部血管成像(CTA)患者平均分为3组:A组采用120 k V、350 mg I/L对比剂60 ml,B组采用120 k V、320 mg I/L对比剂50 ml,C组采用100 k V、300 mg I/L对比剂40ml;流速均采用4.5 ml/s;采用对比剂跟踪技术,阈值为110 HU;3组均在注射完对比剂后以相同速率注射生理盐水40 ml。图像后处理采用VR、MPR、CPR、MIP;测量颈动脉不同水平CT值,观察锁骨下静脉、头臂静脉有无残留对比剂造成的伪影,统计每个病人接受的辐射剂量。结果 3组病例颈动脉内对比剂浓度均大于250 HU以上,无统计学意义(P<0.05);3组图像均满足诊断要求;但在锁骨下静脉和头臂静脉残留对比剂的干扰方面存在差异,差异具有统计学意义(P<0.05),C组图像质量明显优于A、B组;且辐射剂量减少12.83%~13.12%。结论三低技术联合生理盐水技术在256层头颈部CTA成像中是可行的,既能保证图像质量、降低辐射剂量和对比剂用量,又能满足诊断要求。 Objective To investigate the value of three-low technique( low tube voltage. low-dose and low-concentration contrast) combined saline in 256-slice CTA of the head and neck,which can reduce radiation dosage and adverse effect of contrast. Methods 120 cases examined by CTA in the head and neck were divided into 3 groups: Group A scanning parameters: 120 k V and amout of contrast agent: 350 mg I / L,60 ml; Group B scanning parameters: 120 k V and amout of contrast agent: 320 mg I / L,50 ml; Group C scanning parameters: 100 k V and amout of contrast agent: 300 mg I / L 40 ml; The rate was 4. 5ml / s,with bolus trigger technique. The threshold was 110 HU; 40 m L saline was injected in the same rate after injecting contrast. Imaging postprocessing techniques include VR,MIP,CPR,MPR; Measure CT values of the different level of Carotid arteries; observe the artifact of the remaining contrast in the subclavian vein and brachiocephalic vein,and record radiation dosage of patients. Results All CT values of the contrast in Carotid arteries were more than 240 HU. There was no statistical difference among three groups. All images could meet the diagnostic requirements. The artifact of the remaining contrast in the three groups,the image quality of group C was better than those of group A and group B. The radiation dosage reduced to 12.83 ~ 13. 12%. Conclusion Application of the low tube voltage. low-dose and low-concentration contrast combined saline in256-slice CTA of the head and neck was feasible. It is not only improve the image quality,reduce radiation dosage and amout of contrast,but also meet the diagnostic requirements.
机构地区 解放军
出处 《中国辐射卫生》 2015年第5期574-576,共3页 Chinese Journal of Radiological Health
关键词 低管电压 对比剂 生理盐水 辐射剂量 CTA Tomography X-Ray Computed Low Tube Voltage Contrast Saline Radiation Dosage CT Angiography
  • 相关文献

参考文献6

二级参考文献27

  • 1周阳泱,韩萍,冯敢生,陈祖云,杨想军,李友林,雷子乔,R.Sokiranski.鼻窦低剂量CT扫描对图像质量影响的研究[J].中华放射学杂志,2005,39(3):239-243. 被引量:68
  • 2亓恒涛,秦维昌,柳澄,王道才,刘传亚,王巍.64层螺旋CT颞骨低剂量扫描的初步研究[J].中华放射学杂志,2007,41(2):117-120. 被引量:30
  • 3Haaga JR Radiation dose management:weighing risk versus benefit.AJR,2001,177:289-291.
  • 4Jones TR, Kaplan RT, Lane B,et al. Single-versus multi-detector row CT of the brain: quality assessment. Radiology, 2001, 219:750
  • 5Hollingworth W, Nathens AB, Kanne JP,et al. The diagnostic accuracy of computed tomography angiography for traumatic or atherosclerotic lesions of the carotid and vertebral arteries: a systematic review. Eur J Radiolt, 2003, 48:88
  • 6Rubin GD, Shiau M, Leung AN,et al. Aorta and iliac arteries: single versus multiple detector row helical CT angiography. Radiology, 2000, 215:670
  • 7Tomandl BF, Klotz E, Handschu R,et al. Comprehensive imaging of ischemic stroke with multisection. Radiographics, 2003, 23:565
  • 8Foley WD, Karcaaltincaba M. Computed tomography angiography: principles and clinical applications. JCAT, 2003, 1:23
  • 9Brink JA. Contrast optimization and scan timing for single and multidetector-row computed tomography. JCTA, 2003, 1:3
  • 10Randoux B, Marro B, Koskas F,et al. Carotid artery stenosis: prospective comparison of CT, three-dimensional gadolinium-enhanced MR, and conventional angiography. Radiology, 2001, 220:179

共引文献114

同被引文献49

引证文献6

二级引证文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部